{"title":"CT成像技术对血液透析器血流的观察","authors":"Junfeng Lu","doi":"10.1109/FSKD.2008.39","DOIUrl":null,"url":null,"abstract":"Intact method for flow analysis in a hemo-dialyzer is highly desired for the design of hemo-dialyzer or in the ongoing hemodialysis process. MRI and CT imaging technologies have been widely used as tools for tissue, bone, and cancerous clinical analysis etc. In this paper, CT imaging technology is adopted to describe flow pattern within a hemo-dialyzer. And then, an intact image analysis method trying to measure blood flow rate is proposed.","PeriodicalId":208332,"journal":{"name":"2008 Fifth International Conference on Fuzzy Systems and Knowledge Discovery","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Observation of Blood Flow in Hemo-dialyzer Using CT Imaging Technology\",\"authors\":\"Junfeng Lu\",\"doi\":\"10.1109/FSKD.2008.39\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Intact method for flow analysis in a hemo-dialyzer is highly desired for the design of hemo-dialyzer or in the ongoing hemodialysis process. MRI and CT imaging technologies have been widely used as tools for tissue, bone, and cancerous clinical analysis etc. In this paper, CT imaging technology is adopted to describe flow pattern within a hemo-dialyzer. And then, an intact image analysis method trying to measure blood flow rate is proposed.\",\"PeriodicalId\":208332,\"journal\":{\"name\":\"2008 Fifth International Conference on Fuzzy Systems and Knowledge Discovery\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Fifth International Conference on Fuzzy Systems and Knowledge Discovery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FSKD.2008.39\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Fifth International Conference on Fuzzy Systems and Knowledge Discovery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FSKD.2008.39","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Observation of Blood Flow in Hemo-dialyzer Using CT Imaging Technology
Intact method for flow analysis in a hemo-dialyzer is highly desired for the design of hemo-dialyzer or in the ongoing hemodialysis process. MRI and CT imaging technologies have been widely used as tools for tissue, bone, and cancerous clinical analysis etc. In this paper, CT imaging technology is adopted to describe flow pattern within a hemo-dialyzer. And then, an intact image analysis method trying to measure blood flow rate is proposed.