{"title":"以人为本的室内室内人工照明设计","authors":"S. Aliparast, S. Onaygil","doi":"10.25039/x48.2021.po42","DOIUrl":null,"url":null,"abstract":"Human centric lighting (HCL) is the sum of visual and non-visual effects of light on humans. According to the results of the research carried out to date it is explained that lighting design results for cell office should reach EML (Equivalent Melanopic Lux) higher than 250 and CS (Circadian Stimulus) approximately 0.4-0.3 at office hours 8:00 AM – 5:00 PM. This study is an alternative lighting design were created in which EML and CS criteria values are specified in cell office without receiving daylight. Artificial electrical lighting design should be analysed in order to deliver an optimal circadian lighting that can help to increase occupant’s productivity, performance and decreasing energy consumption.","PeriodicalId":363368,"journal":{"name":"Proceedings of the Conference CIE 2021","volume":"64 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ARTIFICIAL LIGHTING DESIGN WITH CONCEPT OF HUMAN CENTRIC LIGHTING CRITERIA IN CELL OFFICES\",\"authors\":\"S. Aliparast, S. Onaygil\",\"doi\":\"10.25039/x48.2021.po42\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Human centric lighting (HCL) is the sum of visual and non-visual effects of light on humans. According to the results of the research carried out to date it is explained that lighting design results for cell office should reach EML (Equivalent Melanopic Lux) higher than 250 and CS (Circadian Stimulus) approximately 0.4-0.3 at office hours 8:00 AM – 5:00 PM. This study is an alternative lighting design were created in which EML and CS criteria values are specified in cell office without receiving daylight. Artificial electrical lighting design should be analysed in order to deliver an optimal circadian lighting that can help to increase occupant’s productivity, performance and decreasing energy consumption.\",\"PeriodicalId\":363368,\"journal\":{\"name\":\"Proceedings of the Conference CIE 2021\",\"volume\":\"64 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Conference CIE 2021\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25039/x48.2021.po42\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Conference CIE 2021","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25039/x48.2021.po42","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
ARTIFICIAL LIGHTING DESIGN WITH CONCEPT OF HUMAN CENTRIC LIGHTING CRITERIA IN CELL OFFICES
Human centric lighting (HCL) is the sum of visual and non-visual effects of light on humans. According to the results of the research carried out to date it is explained that lighting design results for cell office should reach EML (Equivalent Melanopic Lux) higher than 250 and CS (Circadian Stimulus) approximately 0.4-0.3 at office hours 8:00 AM – 5:00 PM. This study is an alternative lighting design were created in which EML and CS criteria values are specified in cell office without receiving daylight. Artificial electrical lighting design should be analysed in order to deliver an optimal circadian lighting that can help to increase occupant’s productivity, performance and decreasing energy consumption.