输电线路关键老化段和热点的识别

J. Heckenbergerova, P. Musílek, M. I. Bhuiyan, D. Koval, E. Pelikán
{"title":"输电线路关键老化段和热点的识别","authors":"J. Heckenbergerova, P. Musílek, M. I. Bhuiyan, D. Koval, E. Pelikán","doi":"10.1109/EEEIC.2010.5489965","DOIUrl":null,"url":null,"abstract":"Localization of hotspots and critical aging segments of transmission lines is important for operation and asset management of power transmission systems. Conductors can lose their tensile strength due to the adverse effects of conductor aging caused by annealing. Although the loss of conductor strength is gradual, it accumulates over time and increases the probability of outages and blackouts. Therefore, it is important to keep track of conductor temperatures over time and in space, in order to identify segments of power transmission network that may require more close attention, repairs, or reinforcements. This paper describes and illustrates a new methodology for localization of hotspots and identification of critical aging segments of power transmission lines. The methodology uses load information and weather conditions derived from historical weather reanalysis to derive a time series of spatially resolved map of conductor temperatures. The temperature map is then used to estimate loss of conductor tensile strength for each span of the transmission line. The process is illustrated for a sample transmission line, using assumed load current and historical weather information spanning a period of five years. The simulation results show that the proposed approach provides information vital for transmission network operating procedures and transmission asset management.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Identification of critical aging segments and hotspots of power transmission lines\",\"authors\":\"J. Heckenbergerova, P. Musílek, M. I. Bhuiyan, D. Koval, E. Pelikán\",\"doi\":\"10.1109/EEEIC.2010.5489965\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Localization of hotspots and critical aging segments of transmission lines is important for operation and asset management of power transmission systems. Conductors can lose their tensile strength due to the adverse effects of conductor aging caused by annealing. Although the loss of conductor strength is gradual, it accumulates over time and increases the probability of outages and blackouts. Therefore, it is important to keep track of conductor temperatures over time and in space, in order to identify segments of power transmission network that may require more close attention, repairs, or reinforcements. This paper describes and illustrates a new methodology for localization of hotspots and identification of critical aging segments of power transmission lines. The methodology uses load information and weather conditions derived from historical weather reanalysis to derive a time series of spatially resolved map of conductor temperatures. The temperature map is then used to estimate loss of conductor tensile strength for each span of the transmission line. The process is illustrated for a sample transmission line, using assumed load current and historical weather information spanning a period of five years. The simulation results show that the proposed approach provides information vital for transmission network operating procedures and transmission asset management.\",\"PeriodicalId\":197298,\"journal\":{\"name\":\"2010 9th International Conference on Environment and Electrical Engineering\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 9th International Conference on Environment and Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEEIC.2010.5489965\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 9th International Conference on Environment and Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC.2010.5489965","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

输电线路热点和关键老化段的定位对输电系统的运行和资产管理具有重要意义。由于退火引起的导体老化的不利影响,导体会失去其抗拉强度。虽然导体强度的损失是逐渐的,但它会随着时间的推移而积累,并增加停电和停电的可能性。因此,跟踪导体温度随时间和空间的变化是很重要的,以便确定可能需要更密切关注、维修或加固的输电网络部分。本文描述并说明了一种新的输电线路热点定位和关键老化段识别方法。该方法使用从历史天气再分析中得出的负载信息和天气条件,得出导线温度的时间序列空间分解图。然后使用温度图来估计输电线路每个跨距的导体抗拉强度损失。该过程以输电线路为例,使用假定的负载电流和跨越五年的历史天气信息。仿真结果表明,该方法为输电网运行流程和输电网资产管理提供了重要的信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Identification of critical aging segments and hotspots of power transmission lines
Localization of hotspots and critical aging segments of transmission lines is important for operation and asset management of power transmission systems. Conductors can lose their tensile strength due to the adverse effects of conductor aging caused by annealing. Although the loss of conductor strength is gradual, it accumulates over time and increases the probability of outages and blackouts. Therefore, it is important to keep track of conductor temperatures over time and in space, in order to identify segments of power transmission network that may require more close attention, repairs, or reinforcements. This paper describes and illustrates a new methodology for localization of hotspots and identification of critical aging segments of power transmission lines. The methodology uses load information and weather conditions derived from historical weather reanalysis to derive a time series of spatially resolved map of conductor temperatures. The temperature map is then used to estimate loss of conductor tensile strength for each span of the transmission line. The process is illustrated for a sample transmission line, using assumed load current and historical weather information spanning a period of five years. The simulation results show that the proposed approach provides information vital for transmission network operating procedures and transmission asset management.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信