{"title":"计算机控制超声成像系统中相位像差校正的两种算法","authors":"Danhua Zhao, G. Trahey","doi":"10.1109/CBMSYS.1990.109376","DOIUrl":null,"url":null,"abstract":"Spatial inhomogeneities in the acoustic velocity of tissues degrade the performance of medical ultrasonic imaging systems. Two algorithms which can correct the phase aberration induced by the inhomogeneities are presented. The first algorithm adjusts the phases of signals transmitted and received from individual channels in a phased array scanner, one group of adjacent elements at a time. The second algorithm is based on the assumption that a phases error profile can be approximated by a sum of sine waves and the phase aberration can be corrected by subtracting components of the sum. Comparisons of the two algorithms are presented.<<ETX>>","PeriodicalId":365366,"journal":{"name":"[1990] Proceedings. Third Annual IEEE Symposium on Computer-Based Medical Systems","volume":"156 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Two algorithms for correcting phase aberration in a computer-controlled ultrasonic imaging system\",\"authors\":\"Danhua Zhao, G. Trahey\",\"doi\":\"10.1109/CBMSYS.1990.109376\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Spatial inhomogeneities in the acoustic velocity of tissues degrade the performance of medical ultrasonic imaging systems. Two algorithms which can correct the phase aberration induced by the inhomogeneities are presented. The first algorithm adjusts the phases of signals transmitted and received from individual channels in a phased array scanner, one group of adjacent elements at a time. The second algorithm is based on the assumption that a phases error profile can be approximated by a sum of sine waves and the phase aberration can be corrected by subtracting components of the sum. Comparisons of the two algorithms are presented.<<ETX>>\",\"PeriodicalId\":365366,\"journal\":{\"name\":\"[1990] Proceedings. Third Annual IEEE Symposium on Computer-Based Medical Systems\",\"volume\":\"156 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[1990] Proceedings. Third Annual IEEE Symposium on Computer-Based Medical Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CBMSYS.1990.109376\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1990] Proceedings. Third Annual IEEE Symposium on Computer-Based Medical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CBMSYS.1990.109376","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Two algorithms for correcting phase aberration in a computer-controlled ultrasonic imaging system
Spatial inhomogeneities in the acoustic velocity of tissues degrade the performance of medical ultrasonic imaging systems. Two algorithms which can correct the phase aberration induced by the inhomogeneities are presented. The first algorithm adjusts the phases of signals transmitted and received from individual channels in a phased array scanner, one group of adjacent elements at a time. The second algorithm is based on the assumption that a phases error profile can be approximated by a sum of sine waves and the phase aberration can be corrected by subtracting components of the sum. Comparisons of the two algorithms are presented.<>