计算机控制超声成像系统中相位像差校正的两种算法

Danhua Zhao, G. Trahey
{"title":"计算机控制超声成像系统中相位像差校正的两种算法","authors":"Danhua Zhao, G. Trahey","doi":"10.1109/CBMSYS.1990.109376","DOIUrl":null,"url":null,"abstract":"Spatial inhomogeneities in the acoustic velocity of tissues degrade the performance of medical ultrasonic imaging systems. Two algorithms which can correct the phase aberration induced by the inhomogeneities are presented. The first algorithm adjusts the phases of signals transmitted and received from individual channels in a phased array scanner, one group of adjacent elements at a time. The second algorithm is based on the assumption that a phases error profile can be approximated by a sum of sine waves and the phase aberration can be corrected by subtracting components of the sum. Comparisons of the two algorithms are presented.<<ETX>>","PeriodicalId":365366,"journal":{"name":"[1990] Proceedings. Third Annual IEEE Symposium on Computer-Based Medical Systems","volume":"156 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Two algorithms for correcting phase aberration in a computer-controlled ultrasonic imaging system\",\"authors\":\"Danhua Zhao, G. Trahey\",\"doi\":\"10.1109/CBMSYS.1990.109376\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Spatial inhomogeneities in the acoustic velocity of tissues degrade the performance of medical ultrasonic imaging systems. Two algorithms which can correct the phase aberration induced by the inhomogeneities are presented. The first algorithm adjusts the phases of signals transmitted and received from individual channels in a phased array scanner, one group of adjacent elements at a time. The second algorithm is based on the assumption that a phases error profile can be approximated by a sum of sine waves and the phase aberration can be corrected by subtracting components of the sum. Comparisons of the two algorithms are presented.<<ETX>>\",\"PeriodicalId\":365366,\"journal\":{\"name\":\"[1990] Proceedings. Third Annual IEEE Symposium on Computer-Based Medical Systems\",\"volume\":\"156 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[1990] Proceedings. Third Annual IEEE Symposium on Computer-Based Medical Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CBMSYS.1990.109376\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1990] Proceedings. Third Annual IEEE Symposium on Computer-Based Medical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CBMSYS.1990.109376","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

组织声速的空间不均匀性降低了医学超声成像系统的性能。提出了两种校正非均匀性引起的相位像差的算法。第一种算法调整从相控阵扫描仪的各个通道发送和接收的信号的相位,一次一组相邻的元素。第二种算法基于这样的假设:相位误差轮廓可以用正弦波的总和来近似,相位像差可以通过减去总和的分量来校正。对两种算法进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Two algorithms for correcting phase aberration in a computer-controlled ultrasonic imaging system
Spatial inhomogeneities in the acoustic velocity of tissues degrade the performance of medical ultrasonic imaging systems. Two algorithms which can correct the phase aberration induced by the inhomogeneities are presented. The first algorithm adjusts the phases of signals transmitted and received from individual channels in a phased array scanner, one group of adjacent elements at a time. The second algorithm is based on the assumption that a phases error profile can be approximated by a sum of sine waves and the phase aberration can be corrected by subtracting components of the sum. Comparisons of the two algorithms are presented.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信