用于不间断电源(UPS)的铅酸蓄电池

H. Schaetzle, D. Boden
{"title":"用于不间断电源(UPS)的铅酸蓄电池","authors":"H. Schaetzle, D. Boden","doi":"10.1109/INTLEC.1979.4793633","DOIUrl":null,"url":null,"abstract":"Lead-acid storage batteries are a vital part of any UPS installation. They supply the emergency power to the load in the event commercial power is interrupted or lost. Today's UPS batteries are specifically designed for their intended applications and differ significantly from those used in communication and switchgear service. Design considerations include plate thickness, separator and retainer materials, system voltage window and specific gravity of the electrolyte. The actual installed capacity of a UPS battery for high rate application can only be accurately determined prior to shipment if the battery is factory tested from float. Laboratory tests indicate that cells that have delivered their full fifteen minute capacity when discharged from open circuit will suffer significant capacity losses, forty percent or more, when discharged from a float condition simulating actual field operation.","PeriodicalId":177302,"journal":{"name":"INTELEC - 1979 International Telecommunications Energy Conference","volume":"254 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1979-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Lead-Acid Storage Batteries for Uninterrupted Power Supply (UPS) Applications\",\"authors\":\"H. Schaetzle, D. Boden\",\"doi\":\"10.1109/INTLEC.1979.4793633\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Lead-acid storage batteries are a vital part of any UPS installation. They supply the emergency power to the load in the event commercial power is interrupted or lost. Today's UPS batteries are specifically designed for their intended applications and differ significantly from those used in communication and switchgear service. Design considerations include plate thickness, separator and retainer materials, system voltage window and specific gravity of the electrolyte. The actual installed capacity of a UPS battery for high rate application can only be accurately determined prior to shipment if the battery is factory tested from float. Laboratory tests indicate that cells that have delivered their full fifteen minute capacity when discharged from open circuit will suffer significant capacity losses, forty percent or more, when discharged from a float condition simulating actual field operation.\",\"PeriodicalId\":177302,\"journal\":{\"name\":\"INTELEC - 1979 International Telecommunications Energy Conference\",\"volume\":\"254 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1979-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"INTELEC - 1979 International Telecommunications Energy Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTLEC.1979.4793633\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"INTELEC - 1979 International Telecommunications Energy Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.1979.4793633","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

铅酸蓄电池是任何UPS装置的重要组成部分。在市电中断或丢失的情况下,它们向负载提供应急电源。今天的UPS电池是专门为其预期应用而设计的,与通信和开关设备中使用的电池有很大不同。设计考虑因素包括板厚、分离器和保持器材料、系统电压窗和电解液的比重。高倍率应用的UPS电池的实际装机容量只有在出厂前通过浮子测试才能准确确定。实验室测试表明,当从开路放电时已提供其全部15分钟容量的电池,在模拟实际现场操作的浮子条件下放电时,将遭受显着的容量损失,40%或更多。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Lead-Acid Storage Batteries for Uninterrupted Power Supply (UPS) Applications
Lead-acid storage batteries are a vital part of any UPS installation. They supply the emergency power to the load in the event commercial power is interrupted or lost. Today's UPS batteries are specifically designed for their intended applications and differ significantly from those used in communication and switchgear service. Design considerations include plate thickness, separator and retainer materials, system voltage window and specific gravity of the electrolyte. The actual installed capacity of a UPS battery for high rate application can only be accurately determined prior to shipment if the battery is factory tested from float. Laboratory tests indicate that cells that have delivered their full fifteen minute capacity when discharged from open circuit will suffer significant capacity losses, forty percent or more, when discharged from a float condition simulating actual field operation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信