{"title":"阵列传感器中元件方向图补偿的实验研究","authors":"K. Awai, D. Aizawa, K. Taira, K. Sawaya","doi":"10.1109/ISEMC.2003.1236621","DOIUrl":null,"url":null,"abstract":"A measurement technique by using equally spaced dipole sensors is presented to estimate undesired electromagnetic source location emitted from electronic equipment in a short time. A compensation method for array element pattern is also proposed. Experimental values of the difference of the amplitude and phase between the received voltage of each array element and that of a single sensor placed at the same position of each array element of array sensor are obtained for the cases of 3-element and 5-element array sensors with the array spacing of 0.5 wavelength and 1 wavelength. It is also shown that the received voltage after compensation using experimental data agrees with the received voltage by scanning a single sensor within 0.4 dB in amplitude and 2.4 degrees in phase.","PeriodicalId":359422,"journal":{"name":"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental study on compensation of element pattern in array sensor\",\"authors\":\"K. Awai, D. Aizawa, K. Taira, K. Sawaya\",\"doi\":\"10.1109/ISEMC.2003.1236621\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A measurement technique by using equally spaced dipole sensors is presented to estimate undesired electromagnetic source location emitted from electronic equipment in a short time. A compensation method for array element pattern is also proposed. Experimental values of the difference of the amplitude and phase between the received voltage of each array element and that of a single sensor placed at the same position of each array element of array sensor are obtained for the cases of 3-element and 5-element array sensors with the array spacing of 0.5 wavelength and 1 wavelength. It is also shown that the received voltage after compensation using experimental data agrees with the received voltage by scanning a single sensor within 0.4 dB in amplitude and 2.4 degrees in phase.\",\"PeriodicalId\":359422,\"journal\":{\"name\":\"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)\",\"volume\":\"54 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2003.1236621\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2003.1236621","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Experimental study on compensation of element pattern in array sensor
A measurement technique by using equally spaced dipole sensors is presented to estimate undesired electromagnetic source location emitted from electronic equipment in a short time. A compensation method for array element pattern is also proposed. Experimental values of the difference of the amplitude and phase between the received voltage of each array element and that of a single sensor placed at the same position of each array element of array sensor are obtained for the cases of 3-element and 5-element array sensors with the array spacing of 0.5 wavelength and 1 wavelength. It is also shown that the received voltage after compensation using experimental data agrees with the received voltage by scanning a single sensor within 0.4 dB in amplitude and 2.4 degrees in phase.