一种在临床实验室设置中减少样品检索的可靠方法,无需增加投资。

Anurag Yadav, Ramlingareddy, Avinash Ss, M. M.
{"title":"一种在临床实验室设置中减少样品检索的可靠方法,无需增加投资。","authors":"Anurag Yadav, Ramlingareddy, Avinash Ss, M. M.","doi":"10.35503/ijmlr.2022.7203","DOIUrl":null,"url":null,"abstract":"Background: The concept of Total Laboratory Automation (TLA) is shifting towards the automation in individual process i.e., Task Targeted automation (TTA). Sample storage is one of the key areas in the Total Testing Process (TTP), hence we developed a robust method to reduce the TAT for blood sample retrieval in clinical biochemistry laboratory with zero added investment. We compared the sample retrieval time (TAT) improvement in sample retrieval with the old conventional and the new method of sample storage. Material and method: study was conducted at a medium-large scale lab with average sample of 1000-1200 per day. The blood sample vacutainers are stored in the refrigerator at controlled temperature for the duration of 48hrs as the lab policy. We requested the technicians to retrieve 10 patient samples from the storage for the duration of 5 days, with different person allotted each day. The samples for day were stored and retrieved the requested sample by conventional & new method. Result: our new method has shown a good improvement in the TAT for the retrieval of the stored blood sample for the retesting or the added parameter for testing on request. The conventional method had an average time to identify and retrieve sample was 9.2mins, which was significantly decreased to 1.4mins with the new method of sample storage and retrieval system. Conclusion: Study emphasis this procedure / process will help the small and medium scale laboratories in having a robust method of sample storage and retrieval at a very short TAT with a minimal or no extra investment.","PeriodicalId":420042,"journal":{"name":"International Journal of Medical Laboratory Research","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"“A ROBUST METHOD FOR REDUCING SAMPLE RETRIEVAL TAT IN CLINICAL LABORATORY SETUP AT ZERO ADDED INVESTMENT.”\",\"authors\":\"Anurag Yadav, Ramlingareddy, Avinash Ss, M. M.\",\"doi\":\"10.35503/ijmlr.2022.7203\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: The concept of Total Laboratory Automation (TLA) is shifting towards the automation in individual process i.e., Task Targeted automation (TTA). Sample storage is one of the key areas in the Total Testing Process (TTP), hence we developed a robust method to reduce the TAT for blood sample retrieval in clinical biochemistry laboratory with zero added investment. We compared the sample retrieval time (TAT) improvement in sample retrieval with the old conventional and the new method of sample storage. Material and method: study was conducted at a medium-large scale lab with average sample of 1000-1200 per day. The blood sample vacutainers are stored in the refrigerator at controlled temperature for the duration of 48hrs as the lab policy. We requested the technicians to retrieve 10 patient samples from the storage for the duration of 5 days, with different person allotted each day. The samples for day were stored and retrieved the requested sample by conventional & new method. Result: our new method has shown a good improvement in the TAT for the retrieval of the stored blood sample for the retesting or the added parameter for testing on request. The conventional method had an average time to identify and retrieve sample was 9.2mins, which was significantly decreased to 1.4mins with the new method of sample storage and retrieval system. Conclusion: Study emphasis this procedure / process will help the small and medium scale laboratories in having a robust method of sample storage and retrieval at a very short TAT with a minimal or no extra investment.\",\"PeriodicalId\":420042,\"journal\":{\"name\":\"International Journal of Medical Laboratory Research\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Medical Laboratory Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35503/ijmlr.2022.7203\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Medical Laboratory Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35503/ijmlr.2022.7203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:整体实验室自动化(TLA)的概念正在转向单个过程的自动化,即任务目标自动化(TTA)。样品存储是全检测过程(Total Testing Process, TTP)的关键领域之一,因此,我们开发了一种可靠的方法,可以在零投资的情况下降低临床生化实验室血液样本提取的TAT。我们比较了旧的传统和新的样本存储方法在样本检索中的样本检索时间(TAT)的改进。材料和方法:研究在中大型实验室进行,平均每天1000-1200个样本。根据实验室政策,血样真空容器在控制温度下保存在冰箱中48小时。我们要求技术人员从储存库中取出10个患者样本,为期5天,每天分配不同的人。保存一天的样品,并按常规和新方法提取所需样品。结果:新方法在提取已储存的血液样本进行复验或按要求增加检测参数方面有较好的改进。传统方法鉴定和提取样品的平均时间为9.2min,采用新型样品存储和提取系统后,平均时间显著缩短至1.4min。结论:研究重点:该程序/过程将有助于中小型实验室在极短的TAT内拥有可靠的样品存储和检索方法,而无需额外投资。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
“A ROBUST METHOD FOR REDUCING SAMPLE RETRIEVAL TAT IN CLINICAL LABORATORY SETUP AT ZERO ADDED INVESTMENT.”
Background: The concept of Total Laboratory Automation (TLA) is shifting towards the automation in individual process i.e., Task Targeted automation (TTA). Sample storage is one of the key areas in the Total Testing Process (TTP), hence we developed a robust method to reduce the TAT for blood sample retrieval in clinical biochemistry laboratory with zero added investment. We compared the sample retrieval time (TAT) improvement in sample retrieval with the old conventional and the new method of sample storage. Material and method: study was conducted at a medium-large scale lab with average sample of 1000-1200 per day. The blood sample vacutainers are stored in the refrigerator at controlled temperature for the duration of 48hrs as the lab policy. We requested the technicians to retrieve 10 patient samples from the storage for the duration of 5 days, with different person allotted each day. The samples for day were stored and retrieved the requested sample by conventional & new method. Result: our new method has shown a good improvement in the TAT for the retrieval of the stored blood sample for the retesting or the added parameter for testing on request. The conventional method had an average time to identify and retrieve sample was 9.2mins, which was significantly decreased to 1.4mins with the new method of sample storage and retrieval system. Conclusion: Study emphasis this procedure / process will help the small and medium scale laboratories in having a robust method of sample storage and retrieval at a very short TAT with a minimal or no extra investment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信