长交流传输线的简化稳态特性

J. C. del-Pino-López, Pedro Cruz-Romero, A. Gómez-Expósito
{"title":"长交流传输线的简化稳态特性","authors":"J. C. del-Pino-López, Pedro Cruz-Romero, A. Gómez-Expósito","doi":"10.1109/PTC.2015.7232565","DOIUrl":null,"url":null,"abstract":"In this paper, a simplified formulation of the steady-state, distributed-parameter model of AC transmission lines is presented, which is sufficiently accurate in practice for very long lines. The simplification stems from a reduction in the number of parameters involved in the model and provides a better understanding of the effect that the remaining parameters have on the line performance (i.e., transmission capability, power losses, voltage drop, etc.) at different voltage levels and line lengths.","PeriodicalId":193448,"journal":{"name":"2015 IEEE Eindhoven PowerTech","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A simplified steady-state characterization of long AC transmission lines\",\"authors\":\"J. C. del-Pino-López, Pedro Cruz-Romero, A. Gómez-Expósito\",\"doi\":\"10.1109/PTC.2015.7232565\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a simplified formulation of the steady-state, distributed-parameter model of AC transmission lines is presented, which is sufficiently accurate in practice for very long lines. The simplification stems from a reduction in the number of parameters involved in the model and provides a better understanding of the effect that the remaining parameters have on the line performance (i.e., transmission capability, power losses, voltage drop, etc.) at different voltage levels and line lengths.\",\"PeriodicalId\":193448,\"journal\":{\"name\":\"2015 IEEE Eindhoven PowerTech\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Eindhoven PowerTech\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PTC.2015.7232565\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Eindhoven PowerTech","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PTC.2015.7232565","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种简化的交流输电线路稳态分布参数模型,该模型在实际应用中对于超长线路具有足够的精度。简化源于减少模型中相关参数的数量,并提供一个更好的理解的,其余的参数对性能的影响(例如,传输能力、功率损耗、电压下降,等等)在不同的电压水平和线的长度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A simplified steady-state characterization of long AC transmission lines
In this paper, a simplified formulation of the steady-state, distributed-parameter model of AC transmission lines is presented, which is sufficiently accurate in practice for very long lines. The simplification stems from a reduction in the number of parameters involved in the model and provides a better understanding of the effect that the remaining parameters have on the line performance (i.e., transmission capability, power losses, voltage drop, etc.) at different voltage levels and line lengths.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信