谐波滤波分析的时域三相电力系统阻抗建模方法

A. Girgis, W. Quaintance, J. Qiu, E. Makram
{"title":"谐波滤波分析的时域三相电力系统阻抗建模方法","authors":"A. Girgis, W. Quaintance, J. Qiu, E. Makram","doi":"10.1109/ICHPS.1992.559002","DOIUrl":null,"url":null,"abstract":"A time-domain method for impedance modeling of an unbalanced, three-phase power transmission and distribution network using three-phase measurements of bus voltage and injected current waveforms is presented. An impedance model seen at a bus where a harmonic filter is to be installed is calculated for each harmonic frequency, and the effect of placing the filter at the bus is then analyzed at these frequencies. As the configuration or operating condition of the power system varies, the estimated model changes accordingly, provided updated measurements are available. Hence, the effect of the harmonic filter under different system configurations or operating conditions is analyzed, and the information from this analysis is used for online harmonic filter control. Impedance models estimated by the proposed method are applied in filter design and performance analysis with actual recorded data, and the results are presented. >","PeriodicalId":438464,"journal":{"name":"ICHPS V International Conference on Harmonics in Power Systems.","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"37","resultStr":"{\"title\":\"A Time-domain Three-phase Power System Impedance Modeling Approach For Harmonic Filter Analysis\",\"authors\":\"A. Girgis, W. Quaintance, J. Qiu, E. Makram\",\"doi\":\"10.1109/ICHPS.1992.559002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A time-domain method for impedance modeling of an unbalanced, three-phase power transmission and distribution network using three-phase measurements of bus voltage and injected current waveforms is presented. An impedance model seen at a bus where a harmonic filter is to be installed is calculated for each harmonic frequency, and the effect of placing the filter at the bus is then analyzed at these frequencies. As the configuration or operating condition of the power system varies, the estimated model changes accordingly, provided updated measurements are available. Hence, the effect of the harmonic filter under different system configurations or operating conditions is analyzed, and the information from this analysis is used for online harmonic filter control. Impedance models estimated by the proposed method are applied in filter design and performance analysis with actual recorded data, and the results are presented. >\",\"PeriodicalId\":438464,\"journal\":{\"name\":\"ICHPS V International Conference on Harmonics in Power Systems.\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-09-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"37\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ICHPS V International Conference on Harmonics in Power Systems.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHPS.1992.559002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICHPS V International Conference on Harmonics in Power Systems.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHPS.1992.559002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 37

摘要

提出了一种利用三相母线电压和注入电流波形进行不平衡三相输配电网络阻抗建模的时域方法。在要安装谐波滤波器的母线上,计算每个谐波频率的阻抗模型,然后在这些频率上分析在母线上放置滤波器的效果。随着电力系统的配置或运行条件的变化,如果有更新的测量数据,估计的模型也会相应变化。因此,分析了谐波滤波器在不同系统配置或运行条件下的效果,并将分析所得信息用于谐波滤波器的在线控制。将该方法估计的阻抗模型应用于滤波器设计和性能分析,并结合实际记录数据给出了结果。>
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Time-domain Three-phase Power System Impedance Modeling Approach For Harmonic Filter Analysis
A time-domain method for impedance modeling of an unbalanced, three-phase power transmission and distribution network using three-phase measurements of bus voltage and injected current waveforms is presented. An impedance model seen at a bus where a harmonic filter is to be installed is calculated for each harmonic frequency, and the effect of placing the filter at the bus is then analyzed at these frequencies. As the configuration or operating condition of the power system varies, the estimated model changes accordingly, provided updated measurements are available. Hence, the effect of the harmonic filter under different system configurations or operating conditions is analyzed, and the information from this analysis is used for online harmonic filter control. Impedance models estimated by the proposed method are applied in filter design and performance analysis with actual recorded data, and the results are presented. >
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信