高温对基于内部和外部IT仪器的数据中心运行的影响

Mohammad I. Tradat, H. Alissa, K. Nemati, Sadegh Khalili, B. Sammakia, M. Seymour, Russell Tipton
{"title":"高温对基于内部和外部IT仪器的数据中心运行的影响","authors":"Mohammad I. Tradat, H. Alissa, K. Nemati, Sadegh Khalili, B. Sammakia, M. Seymour, Russell Tipton","doi":"10.1109/SEMI-THERM.2017.7896916","DOIUrl":null,"url":null,"abstract":"Today's data centers increasingly rely on environmental data collection and analysis to operate the cooling infrastructure as efficiently as possible and to maintain the reliability of IT equipment. This in turn emphasizes the importance of the quality of data collected and its relevance to the overall operation of the data center. This study presents an experiment based analysis and comparison of environmental and power data collection using two different approaches; one uses a discrete sensor network and smart PDUs, and another uses available data from the installed IT equipment (IPMI data). The comparison looks deeply into the effect of both approaches that are adopted to control data center cooling. In addition, the effect that the Supply Air Temperature (SAT) from the Computer Room Air Handler (CRAH) unit had on the IT equipment was investigated in fully sealed Cold Aisle Containment (CAC) with 100% CPU utilization. It can be observed that the difference between the discrete and IPMI inlet temperature of the IT equipment increased as SAT increased due to the IT fans increasing speed in an attempt to get more cooling and the resulting in negative pressure differential build up inside the containment. Furthermore, the authors identified a value of the supply air temperature at which IT equipment started to ramp up for both approaches of data center cooling and control. The novelty of this study may aid data center operators when making the decision of what monitoring or control scheme to use.","PeriodicalId":442782,"journal":{"name":"2017 33rd Thermal Measurement, Modeling & Management Symposium (SEMI-THERM)","volume":"33 8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Impact of elevated temperature on data center operation based on internal and external IT instrumentation\",\"authors\":\"Mohammad I. Tradat, H. Alissa, K. Nemati, Sadegh Khalili, B. Sammakia, M. Seymour, Russell Tipton\",\"doi\":\"10.1109/SEMI-THERM.2017.7896916\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Today's data centers increasingly rely on environmental data collection and analysis to operate the cooling infrastructure as efficiently as possible and to maintain the reliability of IT equipment. This in turn emphasizes the importance of the quality of data collected and its relevance to the overall operation of the data center. This study presents an experiment based analysis and comparison of environmental and power data collection using two different approaches; one uses a discrete sensor network and smart PDUs, and another uses available data from the installed IT equipment (IPMI data). The comparison looks deeply into the effect of both approaches that are adopted to control data center cooling. In addition, the effect that the Supply Air Temperature (SAT) from the Computer Room Air Handler (CRAH) unit had on the IT equipment was investigated in fully sealed Cold Aisle Containment (CAC) with 100% CPU utilization. It can be observed that the difference between the discrete and IPMI inlet temperature of the IT equipment increased as SAT increased due to the IT fans increasing speed in an attempt to get more cooling and the resulting in negative pressure differential build up inside the containment. Furthermore, the authors identified a value of the supply air temperature at which IT equipment started to ramp up for both approaches of data center cooling and control. The novelty of this study may aid data center operators when making the decision of what monitoring or control scheme to use.\",\"PeriodicalId\":442782,\"journal\":{\"name\":\"2017 33rd Thermal Measurement, Modeling & Management Symposium (SEMI-THERM)\",\"volume\":\"33 8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 33rd Thermal Measurement, Modeling & Management Symposium (SEMI-THERM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SEMI-THERM.2017.7896916\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 33rd Thermal Measurement, Modeling & Management Symposium (SEMI-THERM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SEMI-THERM.2017.7896916","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

当今的数据中心越来越依赖于环境数据收集和分析,以尽可能高效地运行冷却基础设施,并保持IT设备的可靠性。这反过来又强调了所收集数据质量的重要性及其与数据中心整体操作的相关性。本研究提出了一种基于实验的分析和比较,使用两种不同的方法收集环境和电力数据;一个使用离散传感器网络和智能pdu,另一个使用来自已安装的IT设备的可用数据(IPMI数据)。比较深入地探讨了用于控制数据中心冷却的两种方法的效果。此外,在完全密封的冷通道密封(CAC)中,研究了计算机室空气处理器(CRAH)单元的送风温度(SAT)对IT设备的影响,CPU利用率为100%。可以观察到,It设备的分立和IPMI入口温度之间的差异随着SAT的增加而增加,这是由于It风扇为了获得更多的冷却而增加速度,导致容器内的负压差积聚。此外,作者还确定了供气温度的一个值,在这个值上,IT设备开始为数据中心冷却和控制的两种方法升温。这项研究的新颖之处可以帮助数据中心运营商决定使用哪种监控方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of elevated temperature on data center operation based on internal and external IT instrumentation
Today's data centers increasingly rely on environmental data collection and analysis to operate the cooling infrastructure as efficiently as possible and to maintain the reliability of IT equipment. This in turn emphasizes the importance of the quality of data collected and its relevance to the overall operation of the data center. This study presents an experiment based analysis and comparison of environmental and power data collection using two different approaches; one uses a discrete sensor network and smart PDUs, and another uses available data from the installed IT equipment (IPMI data). The comparison looks deeply into the effect of both approaches that are adopted to control data center cooling. In addition, the effect that the Supply Air Temperature (SAT) from the Computer Room Air Handler (CRAH) unit had on the IT equipment was investigated in fully sealed Cold Aisle Containment (CAC) with 100% CPU utilization. It can be observed that the difference between the discrete and IPMI inlet temperature of the IT equipment increased as SAT increased due to the IT fans increasing speed in an attempt to get more cooling and the resulting in negative pressure differential build up inside the containment. Furthermore, the authors identified a value of the supply air temperature at which IT equipment started to ramp up for both approaches of data center cooling and control. The novelty of this study may aid data center operators when making the decision of what monitoring or control scheme to use.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信