太阳能光伏阵列馈电模糊逻辑控制的永磁同步电动机水泵系统驱动

B. N. Kar, P. Samuel, A. Naik
{"title":"太阳能光伏阵列馈电模糊逻辑控制的永磁同步电动机水泵系统驱动","authors":"B. N. Kar, P. Samuel, A. Naik","doi":"10.1109/APSIT52773.2021.9641332","DOIUrl":null,"url":null,"abstract":"The main objective of this paper is to present the vector control of a permanent magnet synchronous motor (PMSM) based upon the fuzzy logic control (FLC) that is utilized in a photovoltaic based water pumping system. The FLC performs well under any system parameter changes, load disturbances, and a sudden change in reference speed for the electrical motor-drive. The pump is driven by a PMSM in vector control mode. The system dynamic response is improved by using a power feed forward term. This accomplishes the goal of effective and efficient water pumping. The proposed system is designed, modelled, and simulated on the MATLAB/Simulink platform. The system's performances at variable atmospheric conditions are investigated.","PeriodicalId":436488,"journal":{"name":"2021 International Conference in Advances in Power, Signal, and Information Technology (APSIT)","volume":"75 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Solar PV Array Fed Fuzzy Logic Controlled PMSM Drive for Water Pumping System\",\"authors\":\"B. N. Kar, P. Samuel, A. Naik\",\"doi\":\"10.1109/APSIT52773.2021.9641332\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main objective of this paper is to present the vector control of a permanent magnet synchronous motor (PMSM) based upon the fuzzy logic control (FLC) that is utilized in a photovoltaic based water pumping system. The FLC performs well under any system parameter changes, load disturbances, and a sudden change in reference speed for the electrical motor-drive. The pump is driven by a PMSM in vector control mode. The system dynamic response is improved by using a power feed forward term. This accomplishes the goal of effective and efficient water pumping. The proposed system is designed, modelled, and simulated on the MATLAB/Simulink platform. The system's performances at variable atmospheric conditions are investigated.\",\"PeriodicalId\":436488,\"journal\":{\"name\":\"2021 International Conference in Advances in Power, Signal, and Information Technology (APSIT)\",\"volume\":\"75 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference in Advances in Power, Signal, and Information Technology (APSIT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APSIT52773.2021.9641332\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference in Advances in Power, Signal, and Information Technology (APSIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APSIT52773.2021.9641332","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文的主要目的是提出基于模糊逻辑控制(FLC)的永磁同步电机(PMSM)矢量控制,并将其应用于光伏水泵系统中。FLC在任何系统参数变化、负载扰动和电机驱动参考速度突然变化的情况下都表现良好。泵是由一个永磁同步电机在矢量控制模式驱动。采用功率前馈项改善了系统的动态响应。这实现了有效和高效抽水的目标。在MATLAB/Simulink平台上对系统进行了设计、建模和仿真。研究了系统在变大气条件下的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Solar PV Array Fed Fuzzy Logic Controlled PMSM Drive for Water Pumping System
The main objective of this paper is to present the vector control of a permanent magnet synchronous motor (PMSM) based upon the fuzzy logic control (FLC) that is utilized in a photovoltaic based water pumping system. The FLC performs well under any system parameter changes, load disturbances, and a sudden change in reference speed for the electrical motor-drive. The pump is driven by a PMSM in vector control mode. The system dynamic response is improved by using a power feed forward term. This accomplishes the goal of effective and efficient water pumping. The proposed system is designed, modelled, and simulated on the MATLAB/Simulink platform. The system's performances at variable atmospheric conditions are investigated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信