{"title":"干扰抑制:通过闭环建模在线优化控制器","authors":"Z. Zang, R. Bitmead, M. Gevers","doi":"10.23919/ACC.1992.4792659","DOIUrl":null,"url":null,"abstract":"Many practical applications of control system design based on input-output measurements permit the repeated application of a system identification procedure operating on closed loop data together with successive refinement of the designed controller. Recently several iterative schemes for mutually enhanced plant identification and robust control design have been proposed [l]-[3]. In this paper we shall analyze the methodology of [1] from the viewpoint of closed loop signal conditioning and investigate the effect of the noise modelling error and plant modelling error on the closed loop performance.","PeriodicalId":297258,"journal":{"name":"1992 American Control Conference","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"40","resultStr":"{\"title\":\"Disturbance Rejection: on-line refinement of controllers by closed loop modelling\",\"authors\":\"Z. Zang, R. Bitmead, M. Gevers\",\"doi\":\"10.23919/ACC.1992.4792659\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Many practical applications of control system design based on input-output measurements permit the repeated application of a system identification procedure operating on closed loop data together with successive refinement of the designed controller. Recently several iterative schemes for mutually enhanced plant identification and robust control design have been proposed [l]-[3]. In this paper we shall analyze the methodology of [1] from the viewpoint of closed loop signal conditioning and investigate the effect of the noise modelling error and plant modelling error on the closed loop performance.\",\"PeriodicalId\":297258,\"journal\":{\"name\":\"1992 American Control Conference\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"40\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1992 American Control Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/ACC.1992.4792659\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1992 American Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/ACC.1992.4792659","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Disturbance Rejection: on-line refinement of controllers by closed loop modelling
Many practical applications of control system design based on input-output measurements permit the repeated application of a system identification procedure operating on closed loop data together with successive refinement of the designed controller. Recently several iterative schemes for mutually enhanced plant identification and robust control design have been proposed [l]-[3]. In this paper we shall analyze the methodology of [1] from the viewpoint of closed loop signal conditioning and investigate the effect of the noise modelling error and plant modelling error on the closed loop performance.