{"title":"电网故障时,采用FCL实现带dfig的风力发电机组不间断运行","authors":"M. Fazli, N. Talebi","doi":"10.1109/EEEIC.2010.5490024","DOIUrl":null,"url":null,"abstract":"The main issue of wind turbines that equipped with doubly fed induction generators (DFIGs) is the grid faults or low voltage ride through capability. In this paper, a new solution for uninterrupted operation of wind turbine driving a DFIG has been proposed during fault condition in the grid. A fault current limiter (FCL) is placed in series with the rotor circuit. During fault condition FCL enters a huge solenoid in the rotor circuit to inhabit increasing of current in the rotor circuit. When the fault is cleared the FCL bypasses the solenoid. A static synchronous compensator (STATCOM) has been applied for supplying required reactive power in faults and steady states. Capability and modeling accuracy of the proposed method confirmed with simulating a sample power system in PSCAD/EMTDC software.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"196 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"A new method for uninterrupted operation of wind turbines equipped with DFIGs during grid faults using FCL\",\"authors\":\"M. Fazli, N. Talebi\",\"doi\":\"10.1109/EEEIC.2010.5490024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main issue of wind turbines that equipped with doubly fed induction generators (DFIGs) is the grid faults or low voltage ride through capability. In this paper, a new solution for uninterrupted operation of wind turbine driving a DFIG has been proposed during fault condition in the grid. A fault current limiter (FCL) is placed in series with the rotor circuit. During fault condition FCL enters a huge solenoid in the rotor circuit to inhabit increasing of current in the rotor circuit. When the fault is cleared the FCL bypasses the solenoid. A static synchronous compensator (STATCOM) has been applied for supplying required reactive power in faults and steady states. Capability and modeling accuracy of the proposed method confirmed with simulating a sample power system in PSCAD/EMTDC software.\",\"PeriodicalId\":197298,\"journal\":{\"name\":\"2010 9th International Conference on Environment and Electrical Engineering\",\"volume\":\"196 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 9th International Conference on Environment and Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEEIC.2010.5490024\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 9th International Conference on Environment and Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC.2010.5490024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A new method for uninterrupted operation of wind turbines equipped with DFIGs during grid faults using FCL
The main issue of wind turbines that equipped with doubly fed induction generators (DFIGs) is the grid faults or low voltage ride through capability. In this paper, a new solution for uninterrupted operation of wind turbine driving a DFIG has been proposed during fault condition in the grid. A fault current limiter (FCL) is placed in series with the rotor circuit. During fault condition FCL enters a huge solenoid in the rotor circuit to inhabit increasing of current in the rotor circuit. When the fault is cleared the FCL bypasses the solenoid. A static synchronous compensator (STATCOM) has been applied for supplying required reactive power in faults and steady states. Capability and modeling accuracy of the proposed method confirmed with simulating a sample power system in PSCAD/EMTDC software.