{"title":"电网故障时,采用FCL实现带dfig的风力发电机组不间断运行","authors":"M. Fazli, N. Talebi","doi":"10.1109/EEEIC.2010.5490024","DOIUrl":null,"url":null,"abstract":"The main issue of wind turbines that equipped with doubly fed induction generators (DFIGs) is the grid faults or low voltage ride through capability. In this paper, a new solution for uninterrupted operation of wind turbine driving a DFIG has been proposed during fault condition in the grid. A fault current limiter (FCL) is placed in series with the rotor circuit. During fault condition FCL enters a huge solenoid in the rotor circuit to inhabit increasing of current in the rotor circuit. When the fault is cleared the FCL bypasses the solenoid. A static synchronous compensator (STATCOM) has been applied for supplying required reactive power in faults and steady states. Capability and modeling accuracy of the proposed method confirmed with simulating a sample power system in PSCAD/EMTDC software.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"196 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"A new method for uninterrupted operation of wind turbines equipped with DFIGs during grid faults using FCL\",\"authors\":\"M. Fazli, N. Talebi\",\"doi\":\"10.1109/EEEIC.2010.5490024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main issue of wind turbines that equipped with doubly fed induction generators (DFIGs) is the grid faults or low voltage ride through capability. In this paper, a new solution for uninterrupted operation of wind turbine driving a DFIG has been proposed during fault condition in the grid. A fault current limiter (FCL) is placed in series with the rotor circuit. During fault condition FCL enters a huge solenoid in the rotor circuit to inhabit increasing of current in the rotor circuit. When the fault is cleared the FCL bypasses the solenoid. A static synchronous compensator (STATCOM) has been applied for supplying required reactive power in faults and steady states. Capability and modeling accuracy of the proposed method confirmed with simulating a sample power system in PSCAD/EMTDC software.\",\"PeriodicalId\":197298,\"journal\":{\"name\":\"2010 9th International Conference on Environment and Electrical Engineering\",\"volume\":\"196 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 9th International Conference on Environment and Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEEIC.2010.5490024\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 9th International Conference on Environment and Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC.2010.5490024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

配备双馈感应发电机(DFIGs)的风力涡轮机的主要问题是电网故障或低电压穿越能力。本文提出了一种在电网故障情况下风力发电机组驱动双馈发电机不间断运行的解决方案。故障限流器(FCL)与转子电路串联。在故障状态下,FCL进入转子电路中的一个巨大的螺线管中,使转子电路中的电流增大。故障清除后,FCL旁路电磁阀。采用静态同步补偿器(STATCOM)来提供故障和稳态所需的无功功率。在PSCAD/EMTDC软件中对电力系统进行了仿真,验证了该方法的有效性和建模精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A new method for uninterrupted operation of wind turbines equipped with DFIGs during grid faults using FCL
The main issue of wind turbines that equipped with doubly fed induction generators (DFIGs) is the grid faults or low voltage ride through capability. In this paper, a new solution for uninterrupted operation of wind turbine driving a DFIG has been proposed during fault condition in the grid. A fault current limiter (FCL) is placed in series with the rotor circuit. During fault condition FCL enters a huge solenoid in the rotor circuit to inhabit increasing of current in the rotor circuit. When the fault is cleared the FCL bypasses the solenoid. A static synchronous compensator (STATCOM) has been applied for supplying required reactive power in faults and steady states. Capability and modeling accuracy of the proposed method confirmed with simulating a sample power system in PSCAD/EMTDC software.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信