Fanqi Xu, Heng Lu, Chen Yang, Ye Tian, Fengnan Chen, Ying Yan, J. Moser
{"title":"一种用于低温恒温器的新型柔性射频微带","authors":"Fanqi Xu, Heng Lu, Chen Yang, Ye Tian, Fengnan Chen, Ying Yan, J. Moser","doi":"10.1109/ECIE52353.2021.00016","DOIUrl":null,"url":null,"abstract":"A flexible radio frequency (RF) microstrip attached to a nanopositioner in a cryostat is presented. It makes it possible to supply RF signals to a device mounted on the nanopositioner without hindering the motion of the positioner. The insertion loss of the microstrip is 1 dB at 3 GHz. The nanopositioner can move freely at 900mK with the microstrip attached to it This kind of flexible RF microstrip is useful for measuring nanomechanical resonators in the cryostat.","PeriodicalId":219763,"journal":{"name":"2021 International Conference on Electronics, Circuits and Information Engineering (ECIE)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A New Flexible Radio Frequency Microstrip Used in Cryostat\",\"authors\":\"Fanqi Xu, Heng Lu, Chen Yang, Ye Tian, Fengnan Chen, Ying Yan, J. Moser\",\"doi\":\"10.1109/ECIE52353.2021.00016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A flexible radio frequency (RF) microstrip attached to a nanopositioner in a cryostat is presented. It makes it possible to supply RF signals to a device mounted on the nanopositioner without hindering the motion of the positioner. The insertion loss of the microstrip is 1 dB at 3 GHz. The nanopositioner can move freely at 900mK with the microstrip attached to it This kind of flexible RF microstrip is useful for measuring nanomechanical resonators in the cryostat.\",\"PeriodicalId\":219763,\"journal\":{\"name\":\"2021 International Conference on Electronics, Circuits and Information Engineering (ECIE)\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Electronics, Circuits and Information Engineering (ECIE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECIE52353.2021.00016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Electronics, Circuits and Information Engineering (ECIE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECIE52353.2021.00016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A New Flexible Radio Frequency Microstrip Used in Cryostat
A flexible radio frequency (RF) microstrip attached to a nanopositioner in a cryostat is presented. It makes it possible to supply RF signals to a device mounted on the nanopositioner without hindering the motion of the positioner. The insertion loss of the microstrip is 1 dB at 3 GHz. The nanopositioner can move freely at 900mK with the microstrip attached to it This kind of flexible RF microstrip is useful for measuring nanomechanical resonators in the cryostat.