{"title":"偶极子和TEM细胞在甚高频产生的电场强度的比较","authors":"Tian Hong Loh, B. Loader, M. Alexander","doi":"10.1109/EMCZUR.2007.4388281","DOIUrl":null,"url":null,"abstract":"The results are presented of an intercomparison of electric field strength generated by calculable dipoles and transverse electromagnetic (TEM) cells from 30 MHz to 100 MHz. An optical electric field sensor (OEFS) is used as the transfer device between an open-area test site (OATS) and two TEM cells. The corresponding calibration factors for the OEFS are measured and compared. The agreement of better than 0.4 dB between the calibration factors obtained in the different facilities gives confidence in the basis of two distinct methods that provide traceability for E-field strength, namely the calculable dipole and the TEM cell.","PeriodicalId":397061,"journal":{"name":"2007 18th International Zurich Symposium on Electromagnetic Compatibility","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Comparison of electric field strength at VHF frequencies generated by dipoles and TEM cells\",\"authors\":\"Tian Hong Loh, B. Loader, M. Alexander\",\"doi\":\"10.1109/EMCZUR.2007.4388281\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The results are presented of an intercomparison of electric field strength generated by calculable dipoles and transverse electromagnetic (TEM) cells from 30 MHz to 100 MHz. An optical electric field sensor (OEFS) is used as the transfer device between an open-area test site (OATS) and two TEM cells. The corresponding calibration factors for the OEFS are measured and compared. The agreement of better than 0.4 dB between the calibration factors obtained in the different facilities gives confidence in the basis of two distinct methods that provide traceability for E-field strength, namely the calculable dipole and the TEM cell.\",\"PeriodicalId\":397061,\"journal\":{\"name\":\"2007 18th International Zurich Symposium on Electromagnetic Compatibility\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-11-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 18th International Zurich Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMCZUR.2007.4388281\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 18th International Zurich Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCZUR.2007.4388281","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

给出了可计算的偶极子和横向电磁(TEM)单元在30 ~ 100 MHz范围内产生的电场强度的相互比较结果。光学电场传感器(OEFS)被用作开放区域测试点(OATS)和两个TEM单元之间的传递装置。测量并比较了OEFS相应的校正因子。在不同设施中获得的校准因子之间的一致性优于0.4 dB,这为两种不同的方法提供了可靠的基础,即可计算的偶极子和TEM细胞。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of electric field strength at VHF frequencies generated by dipoles and TEM cells
The results are presented of an intercomparison of electric field strength generated by calculable dipoles and transverse electromagnetic (TEM) cells from 30 MHz to 100 MHz. An optical electric field sensor (OEFS) is used as the transfer device between an open-area test site (OATS) and two TEM cells. The corresponding calibration factors for the OEFS are measured and compared. The agreement of better than 0.4 dB between the calibration factors obtained in the different facilities gives confidence in the basis of two distinct methods that provide traceability for E-field strength, namely the calculable dipole and the TEM cell.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信