DFIG风电机组不同控制方式对长期电压稳定性的影响

R. R. Londero, C. Affonso, J. P. A. Vieira, U. Bezerra
{"title":"DFIG风电机组不同控制方式对长期电压稳定性的影响","authors":"R. R. Londero, C. Affonso, J. P. A. Vieira, U. Bezerra","doi":"10.1109/ISGTEurope.2012.6465694","DOIUrl":null,"url":null,"abstract":"This paper presents a comprehensive study showing the impacts of different doubly fed induction generator (DFIG) wind turbines control modes on long-term voltage stability. The study considers fixed voltage control and power factor control modes. The analyses also consider the dynamic models of Over Excitation Limiter (OEL) and On Load Tap Changers (OLTC) combined with static and dynamic loads using time domain simulations. A hypothetical network is used for the scenario of 20% load increase. The impact of each control strategy is studied and the resulting change in long-term system stability is quantified, as well as the interactions between OLTC and OEL equipments. The results show that the manner in which DFIGs are operated will have a significant impact on system stability.","PeriodicalId":244881,"journal":{"name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","volume":"124 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Impact of different DFIG wind turbines control modes on long-term voltage stability\",\"authors\":\"R. R. Londero, C. Affonso, J. P. A. Vieira, U. Bezerra\",\"doi\":\"10.1109/ISGTEurope.2012.6465694\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a comprehensive study showing the impacts of different doubly fed induction generator (DFIG) wind turbines control modes on long-term voltage stability. The study considers fixed voltage control and power factor control modes. The analyses also consider the dynamic models of Over Excitation Limiter (OEL) and On Load Tap Changers (OLTC) combined with static and dynamic loads using time domain simulations. A hypothetical network is used for the scenario of 20% load increase. The impact of each control strategy is studied and the resulting change in long-term system stability is quantified, as well as the interactions between OLTC and OEL equipments. The results show that the manner in which DFIGs are operated will have a significant impact on system stability.\",\"PeriodicalId\":244881,\"journal\":{\"name\":\"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)\",\"volume\":\"124 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEurope.2012.6465694\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEurope.2012.6465694","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

本文综合研究了不同双馈感应发电机(DFIG)风力发电机组控制方式对长期电压稳定性的影响。研究考虑了固定电压控制和功率因数控制两种方式。分析还考虑了过励磁限制器(OEL)和有载分接开关(OLTC)结合静态和动态负载的动态模型。对于负载增加20%的场景,使用假设的网络。研究了各种控制策略的影响,量化了系统长期稳定性的变化,以及OLTC和OEL设备之间的相互作用。结果表明,DFIGs的运行方式将对系统的稳定性产生重大影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of different DFIG wind turbines control modes on long-term voltage stability
This paper presents a comprehensive study showing the impacts of different doubly fed induction generator (DFIG) wind turbines control modes on long-term voltage stability. The study considers fixed voltage control and power factor control modes. The analyses also consider the dynamic models of Over Excitation Limiter (OEL) and On Load Tap Changers (OLTC) combined with static and dynamic loads using time domain simulations. A hypothetical network is used for the scenario of 20% load increase. The impact of each control strategy is studied and the resulting change in long-term system stability is quantified, as well as the interactions between OLTC and OEL equipments. The results show that the manner in which DFIGs are operated will have a significant impact on system stability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信