线路电流差动继电器对相导体上的直接雷击的响应

M. Boecker, Genardo T. Corpuz, Glenn Hargrave, Swagata Das, N. Fischer, V. Skendzic
{"title":"线路电流差动继电器对相导体上的直接雷击的响应","authors":"M. Boecker, Genardo T. Corpuz, Glenn Hargrave, Swagata Das, N. Fischer, V. Skendzic","doi":"10.1109/CPRE.2018.8349805","DOIUrl":null,"url":null,"abstract":"This paper describes an event in which lightning struck and discharged current into the phase conductor of a 345 kV transmission line. The magnitude of the lightning discharge was insufficient to lead to a flashover (line insulation breakdown). The paper examines and explains the response of two different line current differential protective relays to this event that was inside their zone of protection.","PeriodicalId":285875,"journal":{"name":"2018 71st Annual Conference for Protective Relay Engineers (CPRE)","volume":"112 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Line current differential relay response to a direct lightning strike on a phase conductor\",\"authors\":\"M. Boecker, Genardo T. Corpuz, Glenn Hargrave, Swagata Das, N. Fischer, V. Skendzic\",\"doi\":\"10.1109/CPRE.2018.8349805\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes an event in which lightning struck and discharged current into the phase conductor of a 345 kV transmission line. The magnitude of the lightning discharge was insufficient to lead to a flashover (line insulation breakdown). The paper examines and explains the response of two different line current differential protective relays to this event that was inside their zone of protection.\",\"PeriodicalId\":285875,\"journal\":{\"name\":\"2018 71st Annual Conference for Protective Relay Engineers (CPRE)\",\"volume\":\"112 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 71st Annual Conference for Protective Relay Engineers (CPRE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPRE.2018.8349805\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 71st Annual Conference for Protective Relay Engineers (CPRE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPRE.2018.8349805","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文叙述了345千伏输电线路中雷电击中并放电电流进入相导体的事件。雷击放电的强度不足以引起闪络(线路绝缘击穿)。本文考察并解释了两种不同线路电流差动保护继电器对发生在其保护区内的这一事件的响应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Line current differential relay response to a direct lightning strike on a phase conductor
This paper describes an event in which lightning struck and discharged current into the phase conductor of a 345 kV transmission line. The magnitude of the lightning discharge was insufficient to lead to a flashover (line insulation breakdown). The paper examines and explains the response of two different line current differential protective relays to this event that was inside their zone of protection.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信