Diana Alves Campos de Araujo, J. A. Moor Neto, Thiago Americano do Brasil, J. Gouvêa, A.R. Lopes Zachi
{"title":"基于ADRC方法的三相并网变流器鲁棒电流控制","authors":"Diana Alves Campos de Araujo, J. A. Moor Neto, Thiago Americano do Brasil, J. Gouvêa, A.R. Lopes Zachi","doi":"10.1109/COBEP53665.2021.9684144","DOIUrl":null,"url":null,"abstract":"This paper addresses the control design of a current mode control for a three-phase voltage source converter. A variant of the Active Disturbance Rejection Control (ADRC) scheme is proposed for comparison with the classical inner control approach. The ADRC method has a straightforward design procedure and has well-known abilities for disturbance rejection and robustness to parametric uncertainties of the system. Theoretical studies are presented and simulation results are discussed by using EMTP-RV environment considering the system Synchronous Reference Frame Control, whose modeling was extracted from the analysis performed in a classical refer-ence.","PeriodicalId":442384,"journal":{"name":"2021 Brazilian Power Electronics Conference (COBEP)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Robust Current Control of Three-Phase Grid-Connected Converters By Using the ADRC Method\",\"authors\":\"Diana Alves Campos de Araujo, J. A. Moor Neto, Thiago Americano do Brasil, J. Gouvêa, A.R. Lopes Zachi\",\"doi\":\"10.1109/COBEP53665.2021.9684144\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper addresses the control design of a current mode control for a three-phase voltage source converter. A variant of the Active Disturbance Rejection Control (ADRC) scheme is proposed for comparison with the classical inner control approach. The ADRC method has a straightforward design procedure and has well-known abilities for disturbance rejection and robustness to parametric uncertainties of the system. Theoretical studies are presented and simulation results are discussed by using EMTP-RV environment considering the system Synchronous Reference Frame Control, whose modeling was extracted from the analysis performed in a classical refer-ence.\",\"PeriodicalId\":442384,\"journal\":{\"name\":\"2021 Brazilian Power Electronics Conference (COBEP)\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 Brazilian Power Electronics Conference (COBEP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/COBEP53665.2021.9684144\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Brazilian Power Electronics Conference (COBEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COBEP53665.2021.9684144","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Robust Current Control of Three-Phase Grid-Connected Converters By Using the ADRC Method
This paper addresses the control design of a current mode control for a three-phase voltage source converter. A variant of the Active Disturbance Rejection Control (ADRC) scheme is proposed for comparison with the classical inner control approach. The ADRC method has a straightforward design procedure and has well-known abilities for disturbance rejection and robustness to parametric uncertainties of the system. Theoretical studies are presented and simulation results are discussed by using EMTP-RV environment considering the system Synchronous Reference Frame Control, whose modeling was extracted from the analysis performed in a classical refer-ence.