一种防止关节镜相机旋转的新装置

B. Sergio, Viera-Artiles Jaime, Valdiande-Gutiérrez José Julian, Grant Andrea
{"title":"一种防止关节镜相机旋转的新装置","authors":"B. Sergio, Viera-Artiles Jaime, Valdiande-Gutiérrez José Julian, Grant Andrea","doi":"10.46889/josr.2021.2307","DOIUrl":null,"url":null,"abstract":"Objective: This experimental study intends to test a novel device for preventing unintentional camera rotation during arthroscopic knee procedures. Methods: The system consists on a multi-axis gyroscopic sensor that can be universally attached to any camera model in the market. A preliminary experience was designed to evaluate the operability of the device during actual arthroscopic meniscectomies. Results: The system provided accurate real-time insight about camera orientation in relation to a selected working plane. The system is more useful when used within the tibio-femoral space and in the anterior (suprapatellar) compartment. Conclusion: This device is able to assist orthopedics trainees and novel surgeons during arthroscopic training, reducing undesired camera rotation, disorientation, fatigue and surgical times.","PeriodicalId":382112,"journal":{"name":"Journal of Orthopaedic Science and Research","volume":"595 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Novel Device to Prevent Undesired Arthroscopic Camera Rotation\",\"authors\":\"B. Sergio, Viera-Artiles Jaime, Valdiande-Gutiérrez José Julian, Grant Andrea\",\"doi\":\"10.46889/josr.2021.2307\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: This experimental study intends to test a novel device for preventing unintentional camera rotation during arthroscopic knee procedures. Methods: The system consists on a multi-axis gyroscopic sensor that can be universally attached to any camera model in the market. A preliminary experience was designed to evaluate the operability of the device during actual arthroscopic meniscectomies. Results: The system provided accurate real-time insight about camera orientation in relation to a selected working plane. The system is more useful when used within the tibio-femoral space and in the anterior (suprapatellar) compartment. Conclusion: This device is able to assist orthopedics trainees and novel surgeons during arthroscopic training, reducing undesired camera rotation, disorientation, fatigue and surgical times.\",\"PeriodicalId\":382112,\"journal\":{\"name\":\"Journal of Orthopaedic Science and Research\",\"volume\":\"595 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Science and Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.46889/josr.2021.2307\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Science and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46889/josr.2021.2307","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:本实验研究旨在测试一种新型装置,用于防止关节镜膝关节手术中意外的相机旋转。方法:该系统由一个多轴陀螺仪传感器组成,该传感器可以普遍安装在市场上任何型号的相机上。我们设计了一个初步的经验来评估该装置在实际关节镜半月板切除术中的可操作性。结果:该系统提供了与选定工作平面相关的相机方向的准确实时洞察。该系统在胫骨-股间隙和前(髌上)腔室使用时更有用。结论:该装置能够在关节镜训练中辅助骨科学员和新型外科医生,减少不必要的摄像机旋转、定向障碍、疲劳和手术时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Novel Device to Prevent Undesired Arthroscopic Camera Rotation
Objective: This experimental study intends to test a novel device for preventing unintentional camera rotation during arthroscopic knee procedures. Methods: The system consists on a multi-axis gyroscopic sensor that can be universally attached to any camera model in the market. A preliminary experience was designed to evaluate the operability of the device during actual arthroscopic meniscectomies. Results: The system provided accurate real-time insight about camera orientation in relation to a selected working plane. The system is more useful when used within the tibio-femoral space and in the anterior (suprapatellar) compartment. Conclusion: This device is able to assist orthopedics trainees and novel surgeons during arthroscopic training, reducing undesired camera rotation, disorientation, fatigue and surgical times.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信