Yinghao Ning, Peng Gao, Yu Sun, Xiaozhi Qi, Ying Hu
{"title":"一种实用的脊柱手术机器人标定方法","authors":"Yinghao Ning, Peng Gao, Yu Sun, Xiaozhi Qi, Ying Hu","doi":"10.1109/ICAR.2017.8023508","DOIUrl":null,"url":null,"abstract":"Surgery robot for pedicle screw placement is explored based on parallel manipulator. To improve the accuracy of parallel manipulator, a practical calibration algorithm is mainly discussed. At the beginning, a novel measurement scheme for calibration is proposed. In order to construct the error model, the propagation of error is analyzed and the procedures for constructing error model are particularly developed. A new algorithm for identifications of parameters is proposed based on particle swarm method. Finally, experiment for calibration is conducted to verify the effectiveness of calibration algorithm. Experiment of pedicle screw placement with spine of pig is carried out to confirm the precision of manipulator after calibration.","PeriodicalId":198633,"journal":{"name":"2017 18th International Conference on Advanced Robotics (ICAR)","volume":"64 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A practical calibration method for spinal surgery robot\",\"authors\":\"Yinghao Ning, Peng Gao, Yu Sun, Xiaozhi Qi, Ying Hu\",\"doi\":\"10.1109/ICAR.2017.8023508\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Surgery robot for pedicle screw placement is explored based on parallel manipulator. To improve the accuracy of parallel manipulator, a practical calibration algorithm is mainly discussed. At the beginning, a novel measurement scheme for calibration is proposed. In order to construct the error model, the propagation of error is analyzed and the procedures for constructing error model are particularly developed. A new algorithm for identifications of parameters is proposed based on particle swarm method. Finally, experiment for calibration is conducted to verify the effectiveness of calibration algorithm. Experiment of pedicle screw placement with spine of pig is carried out to confirm the precision of manipulator after calibration.\",\"PeriodicalId\":198633,\"journal\":{\"name\":\"2017 18th International Conference on Advanced Robotics (ICAR)\",\"volume\":\"64 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 18th International Conference on Advanced Robotics (ICAR)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAR.2017.8023508\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 18th International Conference on Advanced Robotics (ICAR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAR.2017.8023508","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A practical calibration method for spinal surgery robot
Surgery robot for pedicle screw placement is explored based on parallel manipulator. To improve the accuracy of parallel manipulator, a practical calibration algorithm is mainly discussed. At the beginning, a novel measurement scheme for calibration is proposed. In order to construct the error model, the propagation of error is analyzed and the procedures for constructing error model are particularly developed. A new algorithm for identifications of parameters is proposed based on particle swarm method. Finally, experiment for calibration is conducted to verify the effectiveness of calibration algorithm. Experiment of pedicle screw placement with spine of pig is carried out to confirm the precision of manipulator after calibration.