94 GHz固态fm - cw -多普勒雷达廓线仪

D. Klugmann, R. Judaschke
{"title":"94 GHz固态fm - cw -多普勒雷达廓线仪","authors":"D. Klugmann, R. Judaschke","doi":"10.1109/COMEAS.1995.472315","DOIUrl":null,"url":null,"abstract":"Describes a millimetre radar system for the measurement of clouds. The 94 GHz cloud profiler is a bistatic system with an average transmitted power of 1.6 W and it is built up using only semiconductor devices. Due to the modular design power upgrade is possible. It's size without antenna is approx. 65cm/spl times/42cm/spl times/22cm. The weight of the system is about 25 kg. The initial signal is generated by a voltage controlled CW Gunn oscillator. This signal synchronizes a 500 mW IMPATT oscillator by injection locking. The heart of the system is a power combiner consisting of four 500 mW IMPATT oscillators. A fraction ofthe transmitted signal is used as a local oscillator of the mixer which converts the received signal to IF-level. The mixer used for deriving the IF signal from transmitted and received signals has a noise temperature of T=625K at a operation temperature of 300K. The diameter of the antenna used for the first tests is 157 mm.<<ETX>>","PeriodicalId":274878,"journal":{"name":"Conference Proceedings Second Topical Symposium on Combined Optical-Microwave Earth and Atmosphere Sensing","volume":"164 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A 94 GHz solid state FM-CW-Doppler radar profiler\",\"authors\":\"D. Klugmann, R. Judaschke\",\"doi\":\"10.1109/COMEAS.1995.472315\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Describes a millimetre radar system for the measurement of clouds. The 94 GHz cloud profiler is a bistatic system with an average transmitted power of 1.6 W and it is built up using only semiconductor devices. Due to the modular design power upgrade is possible. It's size without antenna is approx. 65cm/spl times/42cm/spl times/22cm. The weight of the system is about 25 kg. The initial signal is generated by a voltage controlled CW Gunn oscillator. This signal synchronizes a 500 mW IMPATT oscillator by injection locking. The heart of the system is a power combiner consisting of four 500 mW IMPATT oscillators. A fraction ofthe transmitted signal is used as a local oscillator of the mixer which converts the received signal to IF-level. The mixer used for deriving the IF signal from transmitted and received signals has a noise temperature of T=625K at a operation temperature of 300K. The diameter of the antenna used for the first tests is 157 mm.<<ETX>>\",\"PeriodicalId\":274878,\"journal\":{\"name\":\"Conference Proceedings Second Topical Symposium on Combined Optical-Microwave Earth and Atmosphere Sensing\",\"volume\":\"164 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Proceedings Second Topical Symposium on Combined Optical-Microwave Earth and Atmosphere Sensing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/COMEAS.1995.472315\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Proceedings Second Topical Symposium on Combined Optical-Microwave Earth and Atmosphere Sensing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COMEAS.1995.472315","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

介绍一种测量云的毫米雷达系统。94 GHz云分析器是一个双基地系统,平均传输功率为1.6 W,仅使用半导体器件构建。由于模块化设计,电源升级是可能的。不带天线的尺寸大约是。65cm/spl倍/42cm/spl倍/22cm。系统重量约为25kg。初始信号由电压控制的连续波Gunn振荡器产生。该信号通过注入锁定同步500mw IMPATT振荡器。系统的核心是一个功率合成器,由四个500mw的IMPATT振荡器组成。发射信号的一部分用作混频器的本地振荡器,它将接收到的信号转换为中频电平。用于从发射和接收信号中导出中频信号的混频器在工作温度为300K时噪声温度T=625K。第一次试验使用的天线直径为157毫米。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A 94 GHz solid state FM-CW-Doppler radar profiler
Describes a millimetre radar system for the measurement of clouds. The 94 GHz cloud profiler is a bistatic system with an average transmitted power of 1.6 W and it is built up using only semiconductor devices. Due to the modular design power upgrade is possible. It's size without antenna is approx. 65cm/spl times/42cm/spl times/22cm. The weight of the system is about 25 kg. The initial signal is generated by a voltage controlled CW Gunn oscillator. This signal synchronizes a 500 mW IMPATT oscillator by injection locking. The heart of the system is a power combiner consisting of four 500 mW IMPATT oscillators. A fraction ofthe transmitted signal is used as a local oscillator of the mixer which converts the received signal to IF-level. The mixer used for deriving the IF signal from transmitted and received signals has a noise temperature of T=625K at a operation temperature of 300K. The diameter of the antenna used for the first tests is 157 mm.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信