Karim Mansouri, Mouna Ben Hamed, L. Sbita, Mehdi Dhaoui
{"title":"低压配电智能电网中使用负荷潮流变化的三相平衡:“L.F.B.M.”","authors":"Karim Mansouri, Mouna Ben Hamed, L. Sbita, Mehdi Dhaoui","doi":"10.1109/STA.2015.7505085","DOIUrl":null,"url":null,"abstract":"Usually, electrical design engineer must take care about three-phase balancing before sending the final version of the LV electric wiring. The conventional method used to verify this task was just to divide all single-phase electrical-loads between the three phases without focusing the consideration on daily load-flow variation of the electrical-loads. For this, this paper describes a necessary new method that must be used in order to balance the three phases in 0.4 KV distribution smart-grids and its implementation and simulation in a Matlab/Simulink model.","PeriodicalId":128530,"journal":{"name":"2015 16th International Conference on Sciences and Techniques of Automatic Control and Computer Engineering (STA)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Three-phase balancing in a LV distribution smart-grids using electrical load flow variation: “L.F.B.M.”\",\"authors\":\"Karim Mansouri, Mouna Ben Hamed, L. Sbita, Mehdi Dhaoui\",\"doi\":\"10.1109/STA.2015.7505085\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Usually, electrical design engineer must take care about three-phase balancing before sending the final version of the LV electric wiring. The conventional method used to verify this task was just to divide all single-phase electrical-loads between the three phases without focusing the consideration on daily load-flow variation of the electrical-loads. For this, this paper describes a necessary new method that must be used in order to balance the three phases in 0.4 KV distribution smart-grids and its implementation and simulation in a Matlab/Simulink model.\",\"PeriodicalId\":128530,\"journal\":{\"name\":\"2015 16th International Conference on Sciences and Techniques of Automatic Control and Computer Engineering (STA)\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 16th International Conference on Sciences and Techniques of Automatic Control and Computer Engineering (STA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/STA.2015.7505085\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 16th International Conference on Sciences and Techniques of Automatic Control and Computer Engineering (STA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/STA.2015.7505085","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Three-phase balancing in a LV distribution smart-grids using electrical load flow variation: “L.F.B.M.”
Usually, electrical design engineer must take care about three-phase balancing before sending the final version of the LV electric wiring. The conventional method used to verify this task was just to divide all single-phase electrical-loads between the three phases without focusing the consideration on daily load-flow variation of the electrical-loads. For this, this paper describes a necessary new method that must be used in order to balance the three phases in 0.4 KV distribution smart-grids and its implementation and simulation in a Matlab/Simulink model.