冷冻组织黑色素瘤太赫兹成像的计算研究

Zoltan Vilagosh, A. Lajevardipour, A. Wood
{"title":"冷冻组织黑色素瘤太赫兹成像的计算研究","authors":"Zoltan Vilagosh, A. Lajevardipour, A. Wood","doi":"10.1109/ICIIBMS.2018.8550018","DOIUrl":null,"url":null,"abstract":"Terahertz radiation is highly absorbed by liquid water, with less than 0.0001% of the signal surviving to a depth of 1.0 millimeter at 0.45 terahertz, limiting the potential for imaging of human tissues. On the other hand, 90% of the terahertz signal survives in ice in the 0.1 to 1.0 terahertz band, opening the possibility of in-vivo imaging of skin lesions, particularly melanomas, to a depth of 5.0 millimeters by first freezing the skin in situ. Computational modelling of THz-frozen skin imaging indicates that contrast exists to differentiate melanomas from normal frozen skin on the basis of water content alone. If the melanin content of melanomas is a significant absorber of terahertz radiation, then melanin becomes the main contrast element. The modelling results justify the further exploration of the imaging technique with the study of ex-vivo frozen melanoma samples before progressing to in-vivo clinical trials.","PeriodicalId":430326,"journal":{"name":"2018 International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Computational Study of Frozen Tissue Melanoma Imagining at Terahertz Frequencies\",\"authors\":\"Zoltan Vilagosh, A. Lajevardipour, A. Wood\",\"doi\":\"10.1109/ICIIBMS.2018.8550018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Terahertz radiation is highly absorbed by liquid water, with less than 0.0001% of the signal surviving to a depth of 1.0 millimeter at 0.45 terahertz, limiting the potential for imaging of human tissues. On the other hand, 90% of the terahertz signal survives in ice in the 0.1 to 1.0 terahertz band, opening the possibility of in-vivo imaging of skin lesions, particularly melanomas, to a depth of 5.0 millimeters by first freezing the skin in situ. Computational modelling of THz-frozen skin imaging indicates that contrast exists to differentiate melanomas from normal frozen skin on the basis of water content alone. If the melanin content of melanomas is a significant absorber of terahertz radiation, then melanin becomes the main contrast element. The modelling results justify the further exploration of the imaging technique with the study of ex-vivo frozen melanoma samples before progressing to in-vivo clinical trials.\",\"PeriodicalId\":430326,\"journal\":{\"name\":\"2018 International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS)\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIIBMS.2018.8550018\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIIBMS.2018.8550018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

太赫兹辐射被液态水高度吸收,只有不到0.0001%的信号在0.45太赫兹下存活到1.0毫米的深度,限制了人体组织成像的潜力。另一方面,90%的太赫兹信号在0.1到1.0太赫兹波段的冰中存活,打开了对皮肤病变,特别是黑色素瘤进行体内成像的可能性,通过首先将皮肤原位冷冻到5.0毫米的深度。太赫兹冷冻皮肤成像的计算模型表明,仅根据含水量就可以区分黑色素瘤和正常冷冻皮肤。如果黑色素瘤的黑色素含量是太赫兹辐射的重要吸收剂,那么黑色素就成为主要的对比元素。建模结果证明了在进行体内临床试验之前,通过对离体冷冻黑色素瘤样本的研究进一步探索成像技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Computational Study of Frozen Tissue Melanoma Imagining at Terahertz Frequencies
Terahertz radiation is highly absorbed by liquid water, with less than 0.0001% of the signal surviving to a depth of 1.0 millimeter at 0.45 terahertz, limiting the potential for imaging of human tissues. On the other hand, 90% of the terahertz signal survives in ice in the 0.1 to 1.0 terahertz band, opening the possibility of in-vivo imaging of skin lesions, particularly melanomas, to a depth of 5.0 millimeters by first freezing the skin in situ. Computational modelling of THz-frozen skin imaging indicates that contrast exists to differentiate melanomas from normal frozen skin on the basis of water content alone. If the melanin content of melanomas is a significant absorber of terahertz radiation, then melanin becomes the main contrast element. The modelling results justify the further exploration of the imaging technique with the study of ex-vivo frozen melanoma samples before progressing to in-vivo clinical trials.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信