{"title":"三维环成形术环修复治疗功能性三尖瓣返流的中期结果","authors":"Osama Rashwan , Abdallah Nosair , Hosam Fathy , Kareem Mahmoud , Alaa Omar","doi":"10.1016/j.jescts.2017.11.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Functional tricuspid regurgitation (TR) is caused by annular dilatation mainly in the posterior annulus. However, ring annuloplasty does not always prevent the recurrence of TR. Tricuspid repair with 3-dimensional Contour 3D ring is claimed to improve functional TR yet the mid and long-term results of repair need to be assessed.</p></div><div><h3>Methods</h3><p>From March 2013 to March 2015, 50 patients with Functional TR secondary to left-sided valve disease underwent tricuspid annuloplasty using the Contour 3D (Medtronic, Minneapolis, MN) ring. All patients underwent concomitant left-sided valve surgery. Follow-up of TR and right ventricular (RV) function were done before hospital discharge and after 12 and 24 months.</p></div><div><h3>Results</h3><p>Mean ring size was 30.5 mm (range 28–36). Hospital mortality was 4%. The follow-up period was 26 ± 6 months. Echocardiography at hospital discharge documented no or mild, moderate, and moderate to severe TR in 76%, 16% and 4% of the patients respectively. Follow-up after one year revealed mild TR in 16% of patients, moderate TR in 16% patients. At 24 months, moderate TR was present in 12% patients, no patient had any evidence of severe TR at 12 and 24 months. Freedom from TR≥ +3 was 100% after 24 months.</p></div><div><h3>Conclusions</h3><p>Tricuspid annuloplasty with the Contour 3D ring provided satisfactory early results in functional TR which remained stable at mid-term follow up. Still long-term results need further follow up and assessment.</p></div>","PeriodicalId":100843,"journal":{"name":"Journal of the Egyptian Society of Cardio-Thoracic Surgery","volume":"25 4","pages":"Pages 316-322"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.jescts.2017.11.002","citationCount":"2","resultStr":"{\"title\":\"Mid-term results of three dimensional annuloplasty ring repair in treating functional tricuspid valve regurgitation\",\"authors\":\"Osama Rashwan , Abdallah Nosair , Hosam Fathy , Kareem Mahmoud , Alaa Omar\",\"doi\":\"10.1016/j.jescts.2017.11.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Functional tricuspid regurgitation (TR) is caused by annular dilatation mainly in the posterior annulus. However, ring annuloplasty does not always prevent the recurrence of TR. Tricuspid repair with 3-dimensional Contour 3D ring is claimed to improve functional TR yet the mid and long-term results of repair need to be assessed.</p></div><div><h3>Methods</h3><p>From March 2013 to March 2015, 50 patients with Functional TR secondary to left-sided valve disease underwent tricuspid annuloplasty using the Contour 3D (Medtronic, Minneapolis, MN) ring. All patients underwent concomitant left-sided valve surgery. Follow-up of TR and right ventricular (RV) function were done before hospital discharge and after 12 and 24 months.</p></div><div><h3>Results</h3><p>Mean ring size was 30.5 mm (range 28–36). Hospital mortality was 4%. The follow-up period was 26 ± 6 months. Echocardiography at hospital discharge documented no or mild, moderate, and moderate to severe TR in 76%, 16% and 4% of the patients respectively. Follow-up after one year revealed mild TR in 16% of patients, moderate TR in 16% patients. At 24 months, moderate TR was present in 12% patients, no patient had any evidence of severe TR at 12 and 24 months. Freedom from TR≥ +3 was 100% after 24 months.</p></div><div><h3>Conclusions</h3><p>Tricuspid annuloplasty with the Contour 3D ring provided satisfactory early results in functional TR which remained stable at mid-term follow up. Still long-term results need further follow up and assessment.</p></div>\",\"PeriodicalId\":100843,\"journal\":{\"name\":\"Journal of the Egyptian Society of Cardio-Thoracic Surgery\",\"volume\":\"25 4\",\"pages\":\"Pages 316-322\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.jescts.2017.11.002\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Egyptian Society of Cardio-Thoracic Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1110578X17302031\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Egyptian Society of Cardio-Thoracic Surgery","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1110578X17302031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
背景:功能性三尖瓣反流(TR)主要是由后环扩张引起的。然而,环环成形术并不总能预防TR的复发。三维轮廓三维环修复三尖瓣声称可以改善TR的功能,但修复的中长期结果需要评估。方法2013年3月至2015年3月,50例继发于左侧瓣膜疾病的功能性TR患者采用Contour 3D (Medtronic, Minneapolis, MN)环进行三尖瓣成形术。所有患者均行左侧瓣膜手术。出院前、出院后12个月、出院后24个月随访患者TR、右心室功能。结果平均环径为30.5 mm(28 ~ 36)。医院死亡率为4%。随访26±6个月。出院时超声心动图分别显示76%、16%和4%的患者无或轻度、中度和中度至重度TR。一年后的随访显示16%的患者有轻度TR, 16%的患者有中度TR。在24个月时,12%的患者出现中度TR,没有患者在12个月和24个月时出现严重TR的证据。24个月后,TR≥+3的自由度为100%。结论采用Contour三维环对功能性TR行尖瓣成形术,早期疗效满意,中期随访稳定。但长期结果仍需进一步跟进和评估。
Mid-term results of three dimensional annuloplasty ring repair in treating functional tricuspid valve regurgitation
Background
Functional tricuspid regurgitation (TR) is caused by annular dilatation mainly in the posterior annulus. However, ring annuloplasty does not always prevent the recurrence of TR. Tricuspid repair with 3-dimensional Contour 3D ring is claimed to improve functional TR yet the mid and long-term results of repair need to be assessed.
Methods
From March 2013 to March 2015, 50 patients with Functional TR secondary to left-sided valve disease underwent tricuspid annuloplasty using the Contour 3D (Medtronic, Minneapolis, MN) ring. All patients underwent concomitant left-sided valve surgery. Follow-up of TR and right ventricular (RV) function were done before hospital discharge and after 12 and 24 months.
Results
Mean ring size was 30.5 mm (range 28–36). Hospital mortality was 4%. The follow-up period was 26 ± 6 months. Echocardiography at hospital discharge documented no or mild, moderate, and moderate to severe TR in 76%, 16% and 4% of the patients respectively. Follow-up after one year revealed mild TR in 16% of patients, moderate TR in 16% patients. At 24 months, moderate TR was present in 12% patients, no patient had any evidence of severe TR at 12 and 24 months. Freedom from TR≥ +3 was 100% after 24 months.
Conclusions
Tricuspid annuloplasty with the Contour 3D ring provided satisfactory early results in functional TR which remained stable at mid-term follow up. Still long-term results need further follow up and assessment.