Zhou Liu, Zhe Chen, Chengxi Liu, Haishun Sun, Yanting Hu
{"title":"基于多智能体的广域级联事件防护系统","authors":"Zhou Liu, Zhe Chen, Chengxi Liu, Haishun Sun, Yanting Hu","doi":"10.1109/ASSCC.2012.6523309","DOIUrl":null,"url":null,"abstract":"In this paper, a multi-agent system based wide area protection scheme is proposed in order to prevent long term voltage instability induced cascading events. The distributed relays and controllers work as a device agent which not only executes the normal function automatically but also can be modified to fulfill the extra function according to external requirements. The control center is designed as a highest level agent in MAS to coordinate all the lower agents to prevent the system wide voltage disturbance. A hybrid simulation platform with MATLAB and RTDS is set up to demonstrate the effectiveness of proposed protection strategy. The simulation results indicate that the proposed multi agent control system can effectively coordinate the distributed relays and controllers to prevent the long term voltage instability induced cascading events.","PeriodicalId":341348,"journal":{"name":"2012 10th International Power & Energy Conference (IPEC)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Multi agent system based wide area protection against cascading events\",\"authors\":\"Zhou Liu, Zhe Chen, Chengxi Liu, Haishun Sun, Yanting Hu\",\"doi\":\"10.1109/ASSCC.2012.6523309\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a multi-agent system based wide area protection scheme is proposed in order to prevent long term voltage instability induced cascading events. The distributed relays and controllers work as a device agent which not only executes the normal function automatically but also can be modified to fulfill the extra function according to external requirements. The control center is designed as a highest level agent in MAS to coordinate all the lower agents to prevent the system wide voltage disturbance. A hybrid simulation platform with MATLAB and RTDS is set up to demonstrate the effectiveness of proposed protection strategy. The simulation results indicate that the proposed multi agent control system can effectively coordinate the distributed relays and controllers to prevent the long term voltage instability induced cascading events.\",\"PeriodicalId\":341348,\"journal\":{\"name\":\"2012 10th International Power & Energy Conference (IPEC)\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 10th International Power & Energy Conference (IPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ASSCC.2012.6523309\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 10th International Power & Energy Conference (IPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASSCC.2012.6523309","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Multi agent system based wide area protection against cascading events
In this paper, a multi-agent system based wide area protection scheme is proposed in order to prevent long term voltage instability induced cascading events. The distributed relays and controllers work as a device agent which not only executes the normal function automatically but also can be modified to fulfill the extra function according to external requirements. The control center is designed as a highest level agent in MAS to coordinate all the lower agents to prevent the system wide voltage disturbance. A hybrid simulation platform with MATLAB and RTDS is set up to demonstrate the effectiveness of proposed protection strategy. The simulation results indicate that the proposed multi agent control system can effectively coordinate the distributed relays and controllers to prevent the long term voltage instability induced cascading events.