{"title":"减小开关装置的7电平多电平逆变器比例谐振电流控制研究","authors":"S. A. Zulkifli, S. Salimin, A. Khairi, Abdul Rahman","doi":"10.1109/SPEC.2018.8635845","DOIUrl":null,"url":null,"abstract":"This project describes the investigation on the Proportional Resonant (PR) control and its performance for a 7-level multilevel inverter using only 5 switches of devices in the single-phase inverter. The performance of the PR control is measured based on the ability of the controller to reduce the harmonic distortion in the inverter output system when connected to a non-linear load. This project is divided into two parts: firstly by using the MATLAB simulation, and then testing the hardware implementation. The results of the multilevel simulation in MATLAB/Simulink show that the implementation of the PR control in the inverter system can reduce the total harmonic distortion caused by the non-linear load; meanwhile, the hardware results show that the PR controller system is applicable and functioning well for generating a 7-step level using TI microcontroller based on current PR control strategy system.","PeriodicalId":335893,"journal":{"name":"2018 IEEE 4th Southern Power Electronics Conference (SPEC)","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Investigation on Proportional Resonant Current Control for 7-Level Multilevel Inverter with Reduced Switching Device\",\"authors\":\"S. A. Zulkifli, S. Salimin, A. Khairi, Abdul Rahman\",\"doi\":\"10.1109/SPEC.2018.8635845\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This project describes the investigation on the Proportional Resonant (PR) control and its performance for a 7-level multilevel inverter using only 5 switches of devices in the single-phase inverter. The performance of the PR control is measured based on the ability of the controller to reduce the harmonic distortion in the inverter output system when connected to a non-linear load. This project is divided into two parts: firstly by using the MATLAB simulation, and then testing the hardware implementation. The results of the multilevel simulation in MATLAB/Simulink show that the implementation of the PR control in the inverter system can reduce the total harmonic distortion caused by the non-linear load; meanwhile, the hardware results show that the PR controller system is applicable and functioning well for generating a 7-step level using TI microcontroller based on current PR control strategy system.\",\"PeriodicalId\":335893,\"journal\":{\"name\":\"2018 IEEE 4th Southern Power Electronics Conference (SPEC)\",\"volume\":\"60 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE 4th Southern Power Electronics Conference (SPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPEC.2018.8635845\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE 4th Southern Power Electronics Conference (SPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEC.2018.8635845","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本课题描述了一种7电平多电平逆变器的比例谐振(PR)控制及其性能的研究,该逆变器仅使用单相逆变器中的5个开关器件。PR控制的性能是根据控制器在连接非线性负载时降低逆变器输出系统谐波失真的能力来衡量的。本课题分为两部分:首先利用MATLAB进行仿真,然后进行硬件实现测试。在MATLAB/Simulink中的多电平仿真结果表明,在逆变器系统中实施PR控制可以降低非线性负载引起的总谐波畸变;同时,硬件测试结果表明,在现有的PR控制策略系统的基础上,所设计的PR控制系统能够很好地应用TI单片机产生7步电平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation on Proportional Resonant Current Control for 7-Level Multilevel Inverter with Reduced Switching Device
This project describes the investigation on the Proportional Resonant (PR) control and its performance for a 7-level multilevel inverter using only 5 switches of devices in the single-phase inverter. The performance of the PR control is measured based on the ability of the controller to reduce the harmonic distortion in the inverter output system when connected to a non-linear load. This project is divided into two parts: firstly by using the MATLAB simulation, and then testing the hardware implementation. The results of the multilevel simulation in MATLAB/Simulink show that the implementation of the PR control in the inverter system can reduce the total harmonic distortion caused by the non-linear load; meanwhile, the hardware results show that the PR controller system is applicable and functioning well for generating a 7-step level using TI microcontroller based on current PR control strategy system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信