光伏单相VSI模糊滑模控制的实验评价

K. Chigane, M. Ouassaid
{"title":"光伏单相VSI模糊滑模控制的实验评价","authors":"K. Chigane, M. Ouassaid","doi":"10.1109/ISAECT53699.2021.9668477","DOIUrl":null,"url":null,"abstract":"This study investigates a Fuzzy-Sliding mode control (Fuzzy-SMC) scheme for a single-phase Voltage Source Inverter (VSI) interfacing a photovoltaic (PV) system. The suggested controller is developed to control the real and reactive power in a robust and smooth way and deal with the system parameter uncertainties and external disturbances. The stability of the obtained control laws is proved according to Lyapunov stability criterion. The effectiveness of the adopted strategy is validated through an experimental verification using a Dspace 1104 real-time implementation board. The experimental results, under different load levels, demonstrate that the Fuzzy-SMC provides enhanced transient performance and lower Total Harmonic Distortion (THD) of the output current and voltage in comparison with SMC.","PeriodicalId":137636,"journal":{"name":"2021 4th International Symposium on Advanced Electrical and Communication Technologies (ISAECT)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Experimental Evaluation of Fuzzy-Sliding Mode Control Applied to A Single Phase VSI For Photovoltaic Application\",\"authors\":\"K. Chigane, M. Ouassaid\",\"doi\":\"10.1109/ISAECT53699.2021.9668477\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study investigates a Fuzzy-Sliding mode control (Fuzzy-SMC) scheme for a single-phase Voltage Source Inverter (VSI) interfacing a photovoltaic (PV) system. The suggested controller is developed to control the real and reactive power in a robust and smooth way and deal with the system parameter uncertainties and external disturbances. The stability of the obtained control laws is proved according to Lyapunov stability criterion. The effectiveness of the adopted strategy is validated through an experimental verification using a Dspace 1104 real-time implementation board. The experimental results, under different load levels, demonstrate that the Fuzzy-SMC provides enhanced transient performance and lower Total Harmonic Distortion (THD) of the output current and voltage in comparison with SMC.\",\"PeriodicalId\":137636,\"journal\":{\"name\":\"2021 4th International Symposium on Advanced Electrical and Communication Technologies (ISAECT)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 4th International Symposium on Advanced Electrical and Communication Technologies (ISAECT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISAECT53699.2021.9668477\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 4th International Symposium on Advanced Electrical and Communication Technologies (ISAECT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISAECT53699.2021.9668477","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

针对与光伏(PV)系统相连接的单相电压源逆变器(VSI),研究了一种模糊滑模控制(Fuzzy-SMC)方案。该控制器能够鲁棒平滑地控制系统的实功率和无功功率,并能处理系统参数的不确定性和外部干扰。根据李雅普诺夫稳定性判据证明了所得到的控制律的稳定性。通过Dspace 1104实时实现板的实验验证了所采用策略的有效性。在不同负载水平下的实验结果表明,与SMC相比,模糊SMC具有更强的暂态性能和更低的输出电流和电压的总谐波失真(THD)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental Evaluation of Fuzzy-Sliding Mode Control Applied to A Single Phase VSI For Photovoltaic Application
This study investigates a Fuzzy-Sliding mode control (Fuzzy-SMC) scheme for a single-phase Voltage Source Inverter (VSI) interfacing a photovoltaic (PV) system. The suggested controller is developed to control the real and reactive power in a robust and smooth way and deal with the system parameter uncertainties and external disturbances. The stability of the obtained control laws is proved according to Lyapunov stability criterion. The effectiveness of the adopted strategy is validated through an experimental verification using a Dspace 1104 real-time implementation board. The experimental results, under different load levels, demonstrate that the Fuzzy-SMC provides enhanced transient performance and lower Total Harmonic Distortion (THD) of the output current and voltage in comparison with SMC.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信