宽带光纤超声水听器探头

C. Mu, S. Umchid, L. Bansal, P. Levin, M. El-Sherif, A. Daryoush
{"title":"宽带光纤超声水听器探头","authors":"C. Mu, S. Umchid, L. Bansal, P. Levin, M. El-Sherif, A. Daryoush","doi":"10.1109/LTIMC.2004.1371014","DOIUrl":null,"url":null,"abstract":"A broadband fiber-optic based hydrophone probe is reported for measurements of acoustic fields at the frequencies up to 100 MHz. The fiber probe with a tip diameter of about 8 microns provides a desirable measurement tool eliminating the need for spatial averaging corrections. Power budget calculation of the fiber sensor set-up indicated that high power (200 mW) laser source is essential to achieve adequate signal-to-noise ratio. The results of the preliminary measurements allowed the probe sensitivity to be determined. Improvements to the measurement arrangements are discussed to bring this sensitivity (about 1.7 mV/MPa) in line with that theoretically calculated (4.3 mV/MPa).","PeriodicalId":317707,"journal":{"name":"Proceedings of the Lightwave Technologies in Instrumentation and Measurement Conference, 2004.","volume":"611 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Broadband fiber optic ultrasound hydrophone probe\",\"authors\":\"C. Mu, S. Umchid, L. Bansal, P. Levin, M. El-Sherif, A. Daryoush\",\"doi\":\"10.1109/LTIMC.2004.1371014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A broadband fiber-optic based hydrophone probe is reported for measurements of acoustic fields at the frequencies up to 100 MHz. The fiber probe with a tip diameter of about 8 microns provides a desirable measurement tool eliminating the need for spatial averaging corrections. Power budget calculation of the fiber sensor set-up indicated that high power (200 mW) laser source is essential to achieve adequate signal-to-noise ratio. The results of the preliminary measurements allowed the probe sensitivity to be determined. Improvements to the measurement arrangements are discussed to bring this sensitivity (about 1.7 mV/MPa) in line with that theoretically calculated (4.3 mV/MPa).\",\"PeriodicalId\":317707,\"journal\":{\"name\":\"Proceedings of the Lightwave Technologies in Instrumentation and Measurement Conference, 2004.\",\"volume\":\"611 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-12-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Lightwave Technologies in Instrumentation and Measurement Conference, 2004.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/LTIMC.2004.1371014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Lightwave Technologies in Instrumentation and Measurement Conference, 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/LTIMC.2004.1371014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

报道了一种基于宽带光纤的水听器探头,用于测量频率高达100mhz的声场。光纤探针的尖端直径约为8微米,提供了理想的测量工具,消除了空间平均校正的需要。光纤传感器装置的功率预算计算表明,要达到足够的信噪比,高功率(200mw)的激光源是必不可少的。初步测量的结果可以确定探针的灵敏度。讨论了对测量安排的改进,以使该灵敏度(约1.7 mV/MPa)与理论计算值(4.3 mV/MPa)一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Broadband fiber optic ultrasound hydrophone probe
A broadband fiber-optic based hydrophone probe is reported for measurements of acoustic fields at the frequencies up to 100 MHz. The fiber probe with a tip diameter of about 8 microns provides a desirable measurement tool eliminating the need for spatial averaging corrections. Power budget calculation of the fiber sensor set-up indicated that high power (200 mW) laser source is essential to achieve adequate signal-to-noise ratio. The results of the preliminary measurements allowed the probe sensitivity to be determined. Improvements to the measurement arrangements are discussed to bring this sensitivity (about 1.7 mV/MPa) in line with that theoretically calculated (4.3 mV/MPa).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信