海上风电低频传输及变频技术研究

Jing Ge, Hongyang Yu, Guoliang Zhao, Zhanfeng Deng, Chaoliang Wang
{"title":"海上风电低频传输及变频技术研究","authors":"Jing Ge, Hongyang Yu, Guoliang Zhao, Zhanfeng Deng, Chaoliang Wang","doi":"10.1109/ei250167.2020.9347016","DOIUrl":null,"url":null,"abstract":"This paper introduces three offshore wind power transmission modes, which are power frequency AC, flexible DC and low-frequency AC. Secondly, the key technologies including parameter design and control strategy of large-capacity AC/AC frequency converter used in low-frequency transmission system are studied. Then, it is verified by system modelling and simulation that one 400 MW offshore wind power transmitted by low-frequency has technical feasibility, and the correctness of parameter design and control strategy is also tested. Finally, it is summarized that within a certain transmission distance, low-frequency transmission mode has better technical and economic performance, and it could be one beneficial alternate mothed of offshore wind power grid-connected to the power frequency mode and flexible DC transmission mode.","PeriodicalId":339798,"journal":{"name":"2020 IEEE 4th Conference on Energy Internet and Energy System Integration (EI2)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Research on Low-Frequency Offshore Wind Power Transmission and Frequency Conversion Technology\",\"authors\":\"Jing Ge, Hongyang Yu, Guoliang Zhao, Zhanfeng Deng, Chaoliang Wang\",\"doi\":\"10.1109/ei250167.2020.9347016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper introduces three offshore wind power transmission modes, which are power frequency AC, flexible DC and low-frequency AC. Secondly, the key technologies including parameter design and control strategy of large-capacity AC/AC frequency converter used in low-frequency transmission system are studied. Then, it is verified by system modelling and simulation that one 400 MW offshore wind power transmitted by low-frequency has technical feasibility, and the correctness of parameter design and control strategy is also tested. Finally, it is summarized that within a certain transmission distance, low-frequency transmission mode has better technical and economic performance, and it could be one beneficial alternate mothed of offshore wind power grid-connected to the power frequency mode and flexible DC transmission mode.\",\"PeriodicalId\":339798,\"journal\":{\"name\":\"2020 IEEE 4th Conference on Energy Internet and Energy System Integration (EI2)\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 4th Conference on Energy Internet and Energy System Integration (EI2)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ei250167.2020.9347016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 4th Conference on Energy Internet and Energy System Integration (EI2)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ei250167.2020.9347016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

介绍了工频交流、柔性直流和低频交流三种海上风电传输方式。其次,研究了用于低频传输系统的大容量交/交变频器的参数设计和控制策略等关键技术。然后,通过系统建模和仿真验证了某400mw海上风电低频输电具有技术可行性,并验证了参数设计和控制策略的正确性。最后总结出,在一定传输距离内,低频传输方式具有较好的技术经济性能,可以作为海上风电并网工频方式和灵活直流传输方式的一种有益替代方式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Research on Low-Frequency Offshore Wind Power Transmission and Frequency Conversion Technology
This paper introduces three offshore wind power transmission modes, which are power frequency AC, flexible DC and low-frequency AC. Secondly, the key technologies including parameter design and control strategy of large-capacity AC/AC frequency converter used in low-frequency transmission system are studied. Then, it is verified by system modelling and simulation that one 400 MW offshore wind power transmitted by low-frequency has technical feasibility, and the correctness of parameter design and control strategy is also tested. Finally, it is summarized that within a certain transmission distance, low-frequency transmission mode has better technical and economic performance, and it could be one beneficial alternate mothed of offshore wind power grid-connected to the power frequency mode and flexible DC transmission mode.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信