三电平变频器永磁同步电机驱动系统优化运行方法研究

J. Itoh, D. Sato, T. Tanaka
{"title":"三电平变频器永磁同步电机驱动系统优化运行方法研究","authors":"J. Itoh, D. Sato, T. Tanaka","doi":"10.1109/ICRERA.2012.6477377","DOIUrl":null,"url":null,"abstract":"In this paper, an optimal converter drive method for Permanent Magnet Synchronous Motor (PMSM) with a 3-level inverter is discussed in terms of loss minimization. The 3-level inverter can change an operation mode between two modulations namely, PWM and 1'pulse modulation at a decided point. In this paper, we discuss the interchange point for the two modulations subject to the total loss of PMSM drive system in regards to the motor speed. First, the analysis on intersection point between PWM and 1'pulse modulation is demonstrated, and then the results show, that the motor drive system achieves the highest efficiency with PWM before the intersection point. On one hand, implementation of 1'pulse modulation can achieve the highest efficiency.","PeriodicalId":239142,"journal":{"name":"2012 International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"241 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Investigation of optimal operation method for Permanent Magnet Synchronous Motor drive system with 3-level inverter\",\"authors\":\"J. Itoh, D. Sato, T. Tanaka\",\"doi\":\"10.1109/ICRERA.2012.6477377\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, an optimal converter drive method for Permanent Magnet Synchronous Motor (PMSM) with a 3-level inverter is discussed in terms of loss minimization. The 3-level inverter can change an operation mode between two modulations namely, PWM and 1'pulse modulation at a decided point. In this paper, we discuss the interchange point for the two modulations subject to the total loss of PMSM drive system in regards to the motor speed. First, the analysis on intersection point between PWM and 1'pulse modulation is demonstrated, and then the results show, that the motor drive system achieves the highest efficiency with PWM before the intersection point. On one hand, implementation of 1'pulse modulation can achieve the highest efficiency.\",\"PeriodicalId\":239142,\"journal\":{\"name\":\"2012 International Conference on Renewable Energy Research and Applications (ICRERA)\",\"volume\":\"241 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Renewable Energy Research and Applications (ICRERA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICRERA.2012.6477377\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Renewable Energy Research and Applications (ICRERA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICRERA.2012.6477377","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

本文从损耗最小化的角度出发,讨论了三电平逆变器永磁同步电动机的最优变换器驱动方法。3电平逆变器可以在PWM和1'脉冲调制两种调制方式之间切换工作模式。在本文中,我们讨论了在永磁同步电机驱动系统的总损耗下,两种调制方式在电机速度方面的交汇点。首先,对PWM与1'脉冲调制的交点进行了分析,结果表明,在交点之前,采用PWM的电机驱动系统效率最高。一方面,实现1'脉冲调制可以达到最高的效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation of optimal operation method for Permanent Magnet Synchronous Motor drive system with 3-level inverter
In this paper, an optimal converter drive method for Permanent Magnet Synchronous Motor (PMSM) with a 3-level inverter is discussed in terms of loss minimization. The 3-level inverter can change an operation mode between two modulations namely, PWM and 1'pulse modulation at a decided point. In this paper, we discuss the interchange point for the two modulations subject to the total loss of PMSM drive system in regards to the motor speed. First, the analysis on intersection point between PWM and 1'pulse modulation is demonstrated, and then the results show, that the motor drive system achieves the highest efficiency with PWM before the intersection point. On one hand, implementation of 1'pulse modulation can achieve the highest efficiency.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信