{"title":"利用聚合谐波相量跟踪谐波滤波器的性能","authors":"Brandon Peterson, J. Rens, Jan Meyer, Sané Rens","doi":"10.1109/AMPS55790.2022.9978889","DOIUrl":null,"url":null,"abstract":"Harmonic filter bank performance could be affected by network configuration changes. Assessment of filter performance in a distribution network with different distortion sources and dynamic configuration states is needed for evaluation of contractual obligations on harmonic emission. By using aggregated harmonic phasors and identifying the range of harmonic phase angles where the filter causes secondary cancellation of the harmonic voltage phasor, a practical methodology that track harmonic filter performance is proposed. Application is demonstrated by means of field data.","PeriodicalId":253296,"journal":{"name":"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"285 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Tracking harmonic filter performance using aggregated harmonic phasors\",\"authors\":\"Brandon Peterson, J. Rens, Jan Meyer, Sané Rens\",\"doi\":\"10.1109/AMPS55790.2022.9978889\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Harmonic filter bank performance could be affected by network configuration changes. Assessment of filter performance in a distribution network with different distortion sources and dynamic configuration states is needed for evaluation of contractual obligations on harmonic emission. By using aggregated harmonic phasors and identifying the range of harmonic phase angles where the filter causes secondary cancellation of the harmonic voltage phasor, a practical methodology that track harmonic filter performance is proposed. Application is demonstrated by means of field data.\",\"PeriodicalId\":253296,\"journal\":{\"name\":\"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)\",\"volume\":\"285 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AMPS55790.2022.9978889\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AMPS55790.2022.9978889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Tracking harmonic filter performance using aggregated harmonic phasors
Harmonic filter bank performance could be affected by network configuration changes. Assessment of filter performance in a distribution network with different distortion sources and dynamic configuration states is needed for evaluation of contractual obligations on harmonic emission. By using aggregated harmonic phasors and identifying the range of harmonic phase angles where the filter causes secondary cancellation of the harmonic voltage phasor, a practical methodology that track harmonic filter performance is proposed. Application is demonstrated by means of field data.