风云- 4a先进地球同步辐射成像仪在轨性能

Boyang Chen, Changpei Han, Q. Guo, W. Hui, Qiong Wu, Xiuju Li, Yapeng Wu
{"title":"风云- 4a先进地球同步辐射成像仪在轨性能","authors":"Boyang Chen, Changpei Han, Q. Guo, W. Hui, Qiong Wu, Xiuju Li, Yapeng Wu","doi":"10.1117/12.2665856","DOIUrl":null,"url":null,"abstract":"The performance of the Advanced Geosynchronous Radiation Imager (AGRI) onboard the Fengyun-4 (FY-4) satellite was evaluated. The results showed that its performance has approached the international advanced level of similar instruments. A wavelet filter was designed to filter the striping noises of the AGRI, which come from the inconsistency of the spectrum and thus varies with the observed target. The non-uniformity of the whole image was evaluated by weighting the probability variance of its count values. After filtering, the infrared image of the AGRI had a uniform visual effect on a single channel, and the pattern noise was reduced to below 0.2 K, which ensures the uniformity of products such as cloud detection and sea temperature that use the infrared splitting window channels. Furthermore, the AGRI carries the surface source blackbody as the on-orbit radiation calibration benchmark and rotates the north-south scanning mirror to point to the blackbody to obtain the blackbody observation data in each infrared band. In the current mode, the infrared calibration is performed every 15 minutes. The long-term evaluation results showed that the radiation calibration accuracy of the infrared channels of the AGRI was better than 0.5 K, and some of the channels reached 0.2 K. In addition, the long-term monitoring of the sensitivity and radiative cooling of the AGRI has shown the on-orbit variation of the instrument, which provides a reference for the development of the subsequent instrument.","PeriodicalId":258680,"journal":{"name":"Earth and Space From Infrared to Terahertz (ESIT 2022)","volume":"697 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On-orbit performance of Fengyun-4A advanced geosynchronous radiation imager\",\"authors\":\"Boyang Chen, Changpei Han, Q. Guo, W. Hui, Qiong Wu, Xiuju Li, Yapeng Wu\",\"doi\":\"10.1117/12.2665856\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The performance of the Advanced Geosynchronous Radiation Imager (AGRI) onboard the Fengyun-4 (FY-4) satellite was evaluated. The results showed that its performance has approached the international advanced level of similar instruments. A wavelet filter was designed to filter the striping noises of the AGRI, which come from the inconsistency of the spectrum and thus varies with the observed target. The non-uniformity of the whole image was evaluated by weighting the probability variance of its count values. After filtering, the infrared image of the AGRI had a uniform visual effect on a single channel, and the pattern noise was reduced to below 0.2 K, which ensures the uniformity of products such as cloud detection and sea temperature that use the infrared splitting window channels. Furthermore, the AGRI carries the surface source blackbody as the on-orbit radiation calibration benchmark and rotates the north-south scanning mirror to point to the blackbody to obtain the blackbody observation data in each infrared band. In the current mode, the infrared calibration is performed every 15 minutes. The long-term evaluation results showed that the radiation calibration accuracy of the infrared channels of the AGRI was better than 0.5 K, and some of the channels reached 0.2 K. In addition, the long-term monitoring of the sensitivity and radiative cooling of the AGRI has shown the on-orbit variation of the instrument, which provides a reference for the development of the subsequent instrument.\",\"PeriodicalId\":258680,\"journal\":{\"name\":\"Earth and Space From Infrared to Terahertz (ESIT 2022)\",\"volume\":\"697 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Earth and Space From Infrared to Terahertz (ESIT 2022)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2665856\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Earth and Space From Infrared to Terahertz (ESIT 2022)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2665856","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对风云四号(FY-4)卫星上的先进地球同步辐射成像仪(AGRI)的性能进行了评估。结果表明,其性能已接近国际同类仪器的先进水平。设计了一种小波滤波器,用于滤除由光谱不一致引起的条带噪声,该条带噪声随观测目标而变化。通过加权图像计数值的概率方差来评价图像的非均匀性。滤波后的AGRI红外图像在单个通道上具有均匀的视觉效果,图案噪声降至0.2 K以下,保证了云探测、海温等使用红外分窗通道的产品的均匀性。此外,AGRI以地表源黑体为在轨辐射定标基准,旋转南北扫描镜指向黑体,获取各红外波段黑体观测数据。在当前模式下,每15分钟进行一次红外校准。长期评价结果表明,AGRI红外通道辐射定标精度优于0.5 K,部分通道达到0.2 K。此外,对AGRI的灵敏度和辐射冷却的长期监测显示了仪器的在轨变化,为后续仪器的研制提供了参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On-orbit performance of Fengyun-4A advanced geosynchronous radiation imager
The performance of the Advanced Geosynchronous Radiation Imager (AGRI) onboard the Fengyun-4 (FY-4) satellite was evaluated. The results showed that its performance has approached the international advanced level of similar instruments. A wavelet filter was designed to filter the striping noises of the AGRI, which come from the inconsistency of the spectrum and thus varies with the observed target. The non-uniformity of the whole image was evaluated by weighting the probability variance of its count values. After filtering, the infrared image of the AGRI had a uniform visual effect on a single channel, and the pattern noise was reduced to below 0.2 K, which ensures the uniformity of products such as cloud detection and sea temperature that use the infrared splitting window channels. Furthermore, the AGRI carries the surface source blackbody as the on-orbit radiation calibration benchmark and rotates the north-south scanning mirror to point to the blackbody to obtain the blackbody observation data in each infrared band. In the current mode, the infrared calibration is performed every 15 minutes. The long-term evaluation results showed that the radiation calibration accuracy of the infrared channels of the AGRI was better than 0.5 K, and some of the channels reached 0.2 K. In addition, the long-term monitoring of the sensitivity and radiative cooling of the AGRI has shown the on-orbit variation of the instrument, which provides a reference for the development of the subsequent instrument.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信