实验室条件下早期流光发射避雷针与富兰克林避雷针工作特性的对比分析

Mladen S. Banjanin
{"title":"实验室条件下早期流光发射避雷针与富兰克林避雷针工作特性的对比分析","authors":"Mladen S. Banjanin","doi":"10.1109/INFOTEH57020.2023.10094077","DOIUrl":null,"url":null,"abstract":"The paper deals with comparative laboratory tests of operating characteristics of the early streamer emission (ESE) lightning rod and Franklin rod. Laboratory tests are performed by using high direct test voltage, and lightning and switching impulse test voltages. Dependence of the amplitude and frequency of the ESE rod tip voltage on the value of applied high direct test voltage is presented. The upward currents and high frequency pulses at the tip of ESE and Franklin rods, caused by high direct test voltage, are measured. Comparisons of the ESE rod and Franklin rod efficiencies is performed by counting number of flashovers to the tip of each rod, caused by lightning and switching test impulse voltages. Good correlations between the results from different tests are estimated.","PeriodicalId":287923,"journal":{"name":"2023 22nd International Symposium INFOTEH-JAHORINA (INFOTEH)","volume":"93 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative analysis of operating characteristics of the early streamer emission (ESE) lightning rod and Franklin rod under the laboratory conditions\",\"authors\":\"Mladen S. Banjanin\",\"doi\":\"10.1109/INFOTEH57020.2023.10094077\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper deals with comparative laboratory tests of operating characteristics of the early streamer emission (ESE) lightning rod and Franklin rod. Laboratory tests are performed by using high direct test voltage, and lightning and switching impulse test voltages. Dependence of the amplitude and frequency of the ESE rod tip voltage on the value of applied high direct test voltage is presented. The upward currents and high frequency pulses at the tip of ESE and Franklin rods, caused by high direct test voltage, are measured. Comparisons of the ESE rod and Franklin rod efficiencies is performed by counting number of flashovers to the tip of each rod, caused by lightning and switching test impulse voltages. Good correlations between the results from different tests are estimated.\",\"PeriodicalId\":287923,\"journal\":{\"name\":\"2023 22nd International Symposium INFOTEH-JAHORINA (INFOTEH)\",\"volume\":\"93 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 22nd International Symposium INFOTEH-JAHORINA (INFOTEH)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INFOTEH57020.2023.10094077\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 22nd International Symposium INFOTEH-JAHORINA (INFOTEH)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INFOTEH57020.2023.10094077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文对早期流光发射避雷针和富兰克林避雷针的工作特性进行了室内对比试验。实验室试验采用高直接试验电压、雷电和开关脉冲试验电压进行。给出了高直接测试电压对电磁感应棒尖端电压幅值和频率的影响。测量了高直接测试电压在ESE棒和富兰克林棒尖端产生的向上电流和高频脉冲。对ESE棒和富兰克林棒效率的比较是通过计算由雷电和开关测试脉冲电压引起的每个棒尖端的闪络次数来进行的。估计不同试验结果之间具有良好的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative analysis of operating characteristics of the early streamer emission (ESE) lightning rod and Franklin rod under the laboratory conditions
The paper deals with comparative laboratory tests of operating characteristics of the early streamer emission (ESE) lightning rod and Franklin rod. Laboratory tests are performed by using high direct test voltage, and lightning and switching impulse test voltages. Dependence of the amplitude and frequency of the ESE rod tip voltage on the value of applied high direct test voltage is presented. The upward currents and high frequency pulses at the tip of ESE and Franklin rods, caused by high direct test voltage, are measured. Comparisons of the ESE rod and Franklin rod efficiencies is performed by counting number of flashovers to the tip of each rod, caused by lightning and switching test impulse voltages. Good correlations between the results from different tests are estimated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信