脏器呼吸运动对分解指数影响的评价。

Nuclear-Medizin Pub Date : 1975-01-31
J Tolwiński, A Mikolajków
{"title":"脏器呼吸运动对分解指数影响的评价。","authors":"J Tolwiński,&nbsp;A Mikolajków","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The motions of the respiratory movement of the diaphragms were filmed and the character of the motion was evaluated. The line-spread function of a motionless line source was compared with that of a moving source (for two kinds of motion: regular and harmonic). Similar calculations were made for increasing the motion amplitudes of the source and for different values of static resolution. The final dynamic resolution was calculated. The results show that when respiratory motion exceeds 13 mm (which happens in about 50% of clinical examinations) the resolution decreases by more than 25% so that it is necessary to use special methods of eliminating these artefacts.</p>","PeriodicalId":19324,"journal":{"name":"Nuclear-Medizin","volume":"13 4","pages":"355-9"},"PeriodicalIF":0.0000,"publicationDate":"1975-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the effect of respiratory movements of the organs on the resolution index.\",\"authors\":\"J Tolwiński,&nbsp;A Mikolajków\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The motions of the respiratory movement of the diaphragms were filmed and the character of the motion was evaluated. The line-spread function of a motionless line source was compared with that of a moving source (for two kinds of motion: regular and harmonic). Similar calculations were made for increasing the motion amplitudes of the source and for different values of static resolution. The final dynamic resolution was calculated. The results show that when respiratory motion exceeds 13 mm (which happens in about 50% of clinical examinations) the resolution decreases by more than 25% so that it is necessary to use special methods of eliminating these artefacts.</p>\",\"PeriodicalId\":19324,\"journal\":{\"name\":\"Nuclear-Medizin\",\"volume\":\"13 4\",\"pages\":\"355-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1975-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear-Medizin\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear-Medizin","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

拍摄膈肌的呼吸运动并评价其运动特征。比较了静止线源与运动线源的线扩展函数(包括正则和谐波两种运动)。对于增加源的运动幅度和不同的静态分辨率值,也进行了类似的计算。计算了最终的动态分辨率。结果表明,当呼吸运动超过13mm时(约50%的临床检查发生这种情况),分辨率下降超过25%,因此有必要使用特殊的方法来消除这些伪影。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of the effect of respiratory movements of the organs on the resolution index.

The motions of the respiratory movement of the diaphragms were filmed and the character of the motion was evaluated. The line-spread function of a motionless line source was compared with that of a moving source (for two kinds of motion: regular and harmonic). Similar calculations were made for increasing the motion amplitudes of the source and for different values of static resolution. The final dynamic resolution was calculated. The results show that when respiratory motion exceeds 13 mm (which happens in about 50% of clinical examinations) the resolution decreases by more than 25% so that it is necessary to use special methods of eliminating these artefacts.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信