一种用于重症监护监护监测的新型限位报警器

A. Makivirta, A. Kari, E. Koski, T. Sukuvaara
{"title":"一种用于重症监护监护监测的新型限位报警器","authors":"A. Makivirta, A. Kari, E. Koski, T. Sukuvaara","doi":"10.1109/CIC.1989.130530","DOIUrl":null,"url":null,"abstract":"A median filter is combined with narrow adjustable monitoring limits and wide physiologically determined alarm limits. This ensures both quick alarming in the case of a catastrophic failure and reliable therapy monitoring with alarms. Results of the clinical assessment of this dual-limit alarmer are provided. Results of the clinical evaluation indicate a significant reduction in the frequency of false alarm (63% per patient hour).<<ETX>>","PeriodicalId":161494,"journal":{"name":"[1989] Proceedings. Computers in Cardiology","volume":"246 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A novel limit alarmer for reliable intensive care monitoring\",\"authors\":\"A. Makivirta, A. Kari, E. Koski, T. Sukuvaara\",\"doi\":\"10.1109/CIC.1989.130530\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A median filter is combined with narrow adjustable monitoring limits and wide physiologically determined alarm limits. This ensures both quick alarming in the case of a catastrophic failure and reliable therapy monitoring with alarms. Results of the clinical assessment of this dual-limit alarmer are provided. Results of the clinical evaluation indicate a significant reduction in the frequency of false alarm (63% per patient hour).<<ETX>>\",\"PeriodicalId\":161494,\"journal\":{\"name\":\"[1989] Proceedings. Computers in Cardiology\",\"volume\":\"246 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[1989] Proceedings. Computers in Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.1989.130530\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1989] Proceedings. Computers in Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1989.130530","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

中值滤波器结合了窄的可调监测限和宽的生理决定报警限。这确保了在灾难性故障的情况下快速报警和可靠的治疗监测报警。本文提供了双极限报警器的临床评估结果。临床评估结果表明,误报频率显著降低(每患者小时63%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A novel limit alarmer for reliable intensive care monitoring
A median filter is combined with narrow adjustable monitoring limits and wide physiologically determined alarm limits. This ensures both quick alarming in the case of a catastrophic failure and reliable therapy monitoring with alarms. Results of the clinical assessment of this dual-limit alarmer are provided. Results of the clinical evaluation indicate a significant reduction in the frequency of false alarm (63% per patient hour).<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信