{"title":"室外照明装置中紧凑型荧光灯在低温下的性能","authors":"A. Laperrière, R. Martel","doi":"10.1109/IAS.1993.299196","DOIUrl":null,"url":null,"abstract":"Luminaires were installed in a cold environmental chamber. Tests were carried out at 25 degrees C, 10 degrees C, 0 degrees C, -10 degrees C, and -30 degrees C. Illuminance was measured at a fixed distance from the luminaires, and their electrical parameters were studied. Luminaires operated with compact fluorescent lamps (CFLs) in an environment of -30 degrees C are shown to provide less than 30% of the illuminance obtained at 25 degrees C. However, the electrical consumption and power factor are not very sensitive to the ambient temperature. Luminaires with CFLs are not recommended in a cold climate environment such as that of Quebec.<<ETX>>","PeriodicalId":345027,"journal":{"name":"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting","volume":"223 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance of compact fluorescent lamps in exterior lighting fixtures at cold temperature\",\"authors\":\"A. Laperrière, R. Martel\",\"doi\":\"10.1109/IAS.1993.299196\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Luminaires were installed in a cold environmental chamber. Tests were carried out at 25 degrees C, 10 degrees C, 0 degrees C, -10 degrees C, and -30 degrees C. Illuminance was measured at a fixed distance from the luminaires, and their electrical parameters were studied. Luminaires operated with compact fluorescent lamps (CFLs) in an environment of -30 degrees C are shown to provide less than 30% of the illuminance obtained at 25 degrees C. However, the electrical consumption and power factor are not very sensitive to the ambient temperature. Luminaires with CFLs are not recommended in a cold climate environment such as that of Quebec.<<ETX>>\",\"PeriodicalId\":345027,\"journal\":{\"name\":\"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting\",\"volume\":\"223 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1993.299196\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1993.299196","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Performance of compact fluorescent lamps in exterior lighting fixtures at cold temperature
Luminaires were installed in a cold environmental chamber. Tests were carried out at 25 degrees C, 10 degrees C, 0 degrees C, -10 degrees C, and -30 degrees C. Illuminance was measured at a fixed distance from the luminaires, and their electrical parameters were studied. Luminaires operated with compact fluorescent lamps (CFLs) in an environment of -30 degrees C are shown to provide less than 30% of the illuminance obtained at 25 degrees C. However, the electrical consumption and power factor are not very sensitive to the ambient temperature. Luminaires with CFLs are not recommended in a cold climate environment such as that of Quebec.<>