{"title":"胎儿心磁图检测的多通道SQUID系统","authors":"A. Kandori, K. Tsukada, H. Horigome, M. Asaka, S. Shigemitsu, M. Takahashi, Y. Terada, T. Kubo, Akira Matsui, T. Mitsui","doi":"10.1109/ICBEM.1998.666429","DOIUrl":null,"url":null,"abstract":"A nine-channel SQUID magnetometer system is developed to detect weak magnetic fields generated by fetal cardiac activity. The nine 20-mm-diameter axial first-order gradiometers are mounted at intervals of 30 mm. A baseline length of 60 mm is applied to the pickup coil to measure the weak magnetic field from a fetal heart in a deep position. The SQUID is operated with a flux-locked loop (FLL) circuit and the FLL output is recorded at 1 kHz by a computer. Fetal magneto-cardiograms (FMCG) were measured for 109 fetuses of 20 to 39 weeks' gestation. In most cases, maternal MCG interference was negligible. R-wave peaks were detected in 81% of all subjects. The results of FMCG measurements and Fourier analysis of fetal the R-R interval are shown in this paper.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Multichannel SQUID system for detecting fetal magnetocardiograms\",\"authors\":\"A. Kandori, K. Tsukada, H. Horigome, M. Asaka, S. Shigemitsu, M. Takahashi, Y. Terada, T. Kubo, Akira Matsui, T. Mitsui\",\"doi\":\"10.1109/ICBEM.1998.666429\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A nine-channel SQUID magnetometer system is developed to detect weak magnetic fields generated by fetal cardiac activity. The nine 20-mm-diameter axial first-order gradiometers are mounted at intervals of 30 mm. A baseline length of 60 mm is applied to the pickup coil to measure the weak magnetic field from a fetal heart in a deep position. The SQUID is operated with a flux-locked loop (FLL) circuit and the FLL output is recorded at 1 kHz by a computer. Fetal magneto-cardiograms (FMCG) were measured for 109 fetuses of 20 to 39 weeks' gestation. In most cases, maternal MCG interference was negligible. R-wave peaks were detected in 81% of all subjects. The results of FMCG measurements and Fourier analysis of fetal the R-R interval are shown in this paper.\",\"PeriodicalId\":213764,\"journal\":{\"name\":\"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-02-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICBEM.1998.666429\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBEM.1998.666429","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

研制了一种用于检测胎儿心脏活动产生的弱磁场的九通道SQUID磁强计系统。9个直径20毫米的轴向一阶梯度仪每隔30毫米安装一次。采集线圈的基线长度为60毫米,用于测量胎儿心脏深处的弱磁场。SQUID由一个磁通锁定环路(FLL)电路操作,FLL输出由计算机记录在1khz。对109例妊娠20 ~ 39周的胎儿进行了胎心磁图(FMCG)测量。在大多数情况下,母体MCG干扰可以忽略不计。所有受试者中有81%检测到r波峰。本文给出了胎儿R-R区间的FMCG测量和傅里叶分析结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multichannel SQUID system for detecting fetal magnetocardiograms
A nine-channel SQUID magnetometer system is developed to detect weak magnetic fields generated by fetal cardiac activity. The nine 20-mm-diameter axial first-order gradiometers are mounted at intervals of 30 mm. A baseline length of 60 mm is applied to the pickup coil to measure the weak magnetic field from a fetal heart in a deep position. The SQUID is operated with a flux-locked loop (FLL) circuit and the FLL output is recorded at 1 kHz by a computer. Fetal magneto-cardiograms (FMCG) were measured for 109 fetuses of 20 to 39 weeks' gestation. In most cases, maternal MCG interference was negligible. R-wave peaks were detected in 81% of all subjects. The results of FMCG measurements and Fourier analysis of fetal the R-R interval are shown in this paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信