UPFC在电网健康和薄弱部位的性能分析

Mayuree Shegaonkar, M. Gupta, Sourav Das, Deepro Sen, P. Acharjee
{"title":"UPFC在电网健康和薄弱部位的性能分析","authors":"Mayuree Shegaonkar, M. Gupta, Sourav Das, Deepro Sen, P. Acharjee","doi":"10.1109/PEEIC.2018.8665674","DOIUrl":null,"url":null,"abstract":"This paper aims at determining the most suitable zone for the connection of UPFC in a transmission system. Using voltage stability index (VSI), the healthy and weak zones of power system are identified. One UPFC with the same compensation is placed in both healthy and weak zone separately. User friendly Mi-power 9.1 software is applied for real-time simulation with practical security constraints of the power system. IEEE 57-bus system with arbitrarily increased load is considered as a test case. The performance of UPFC is judged by voltage stability enhancement index (VSEI) and reduction of active, reactive power losses and relative environmental pollution deterioration index (REPDI). The test results are compared for all the cases and it reveals that the placement of UPFC in weak zone is the most suitable considering all performance indices.","PeriodicalId":413723,"journal":{"name":"2018 International Conference on Power Energy, Environment and Intelligent Control (PEEIC)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance analysis of UPFC in healthy and weak locations of power system network\",\"authors\":\"Mayuree Shegaonkar, M. Gupta, Sourav Das, Deepro Sen, P. Acharjee\",\"doi\":\"10.1109/PEEIC.2018.8665674\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper aims at determining the most suitable zone for the connection of UPFC in a transmission system. Using voltage stability index (VSI), the healthy and weak zones of power system are identified. One UPFC with the same compensation is placed in both healthy and weak zone separately. User friendly Mi-power 9.1 software is applied for real-time simulation with practical security constraints of the power system. IEEE 57-bus system with arbitrarily increased load is considered as a test case. The performance of UPFC is judged by voltage stability enhancement index (VSEI) and reduction of active, reactive power losses and relative environmental pollution deterioration index (REPDI). The test results are compared for all the cases and it reveals that the placement of UPFC in weak zone is the most suitable considering all performance indices.\",\"PeriodicalId\":413723,\"journal\":{\"name\":\"2018 International Conference on Power Energy, Environment and Intelligent Control (PEEIC)\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference on Power Energy, Environment and Intelligent Control (PEEIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEEIC.2018.8665674\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Power Energy, Environment and Intelligent Control (PEEIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEEIC.2018.8665674","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文旨在确定传输系统中UPFC连接的最合适区域。利用电压稳定指数(VSI)来识别电力系统的健康区和薄弱区。一个具有相同补偿的UPFC分别置于健康区和弱区。采用友好的Mi-power 9.1软件进行实时仿真,并结合电力系统的实际安全约束。以负载任意增加的ieee57总线系统为测试用例。UPFC的性能是通过电压稳定增强指数(VSEI)、有功、无功损耗的减少和相对环境污染恶化指数(REPDI)来判断的。对不同情况下的测试结果进行了比较,综合考虑各性能指标,UPFC放置在弱区是最合适的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance analysis of UPFC in healthy and weak locations of power system network
This paper aims at determining the most suitable zone for the connection of UPFC in a transmission system. Using voltage stability index (VSI), the healthy and weak zones of power system are identified. One UPFC with the same compensation is placed in both healthy and weak zone separately. User friendly Mi-power 9.1 software is applied for real-time simulation with practical security constraints of the power system. IEEE 57-bus system with arbitrarily increased load is considered as a test case. The performance of UPFC is judged by voltage stability enhancement index (VSEI) and reduction of active, reactive power losses and relative environmental pollution deterioration index (REPDI). The test results are compared for all the cases and it reveals that the placement of UPFC in weak zone is the most suitable considering all performance indices.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信