从心电信号中完全去除基线漂移

V. Chouhan, S. Mehta
{"title":"从心电信号中完全去除基线漂移","authors":"V. Chouhan, S. Mehta","doi":"10.1109/ICCTA.2007.126","DOIUrl":null,"url":null,"abstract":"Baseline drift in ECG signal is the biggest hurdle in visualization of correct waveform and computerized detection of wave complexes based on threshold decision. The baseline drift may be linear, static, nonlinear or wavering. Reducing the baseline drift to a near zero value greatly helps in visually inspecting the morphology of the wave components as well as in computerized detection and delineation of the wave complexes. The algorithm is developed for computer implementation using Matlab. It deploys least squares error correction and correction based on overall median of individual single lead data, to reduce baseline drift. QRS complexes are then detected to find RR intervals of the waveform. Finally, median based correction is implemented in the RR interval and a drift free signal is achieved. This can help cardiologists significantly","PeriodicalId":308247,"journal":{"name":"2007 International Conference on Computing: Theory and Applications (ICCTA'07)","volume":"69 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"109","resultStr":"{\"title\":\"Total Removal of Baseline Drift from ECG Signal\",\"authors\":\"V. Chouhan, S. Mehta\",\"doi\":\"10.1109/ICCTA.2007.126\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Baseline drift in ECG signal is the biggest hurdle in visualization of correct waveform and computerized detection of wave complexes based on threshold decision. The baseline drift may be linear, static, nonlinear or wavering. Reducing the baseline drift to a near zero value greatly helps in visually inspecting the morphology of the wave components as well as in computerized detection and delineation of the wave complexes. The algorithm is developed for computer implementation using Matlab. It deploys least squares error correction and correction based on overall median of individual single lead data, to reduce baseline drift. QRS complexes are then detected to find RR intervals of the waveform. Finally, median based correction is implemented in the RR interval and a drift free signal is achieved. This can help cardiologists significantly\",\"PeriodicalId\":308247,\"journal\":{\"name\":\"2007 International Conference on Computing: Theory and Applications (ICCTA'07)\",\"volume\":\"69 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"109\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 International Conference on Computing: Theory and Applications (ICCTA'07)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCTA.2007.126\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 International Conference on Computing: Theory and Applications (ICCTA'07)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCTA.2007.126","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 109

摘要

心电信号的基线漂移是正确波形可视化和基于阈值判断的波复合体计算机检测的最大障碍。基线漂移可以是线性的、静态的、非线性的或摇摆的。将基线漂移降低到接近零的值大大有助于视觉检查波分量的形态以及计算机检测和描绘波复合体。利用Matlab开发了该算法的计算机实现。它部署了最小二乘误差校正和基于单个单个引线数据的总体中位数的校正,以减少基线漂移。然后检测QRS复合物以找到波形的RR间隔。最后,在RR区间内进行基于中值的校正,得到无漂移信号。这对心脏病专家有很大帮助
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Total Removal of Baseline Drift from ECG Signal
Baseline drift in ECG signal is the biggest hurdle in visualization of correct waveform and computerized detection of wave complexes based on threshold decision. The baseline drift may be linear, static, nonlinear or wavering. Reducing the baseline drift to a near zero value greatly helps in visually inspecting the morphology of the wave components as well as in computerized detection and delineation of the wave complexes. The algorithm is developed for computer implementation using Matlab. It deploys least squares error correction and correction based on overall median of individual single lead data, to reduce baseline drift. QRS complexes are then detected to find RR intervals of the waveform. Finally, median based correction is implemented in the RR interval and a drift free signal is achieved. This can help cardiologists significantly
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信