主动冷负荷在微波辐射计标定中的应用挑战

S. Sobjaerg, J. Balling, N. Skou
{"title":"主动冷负荷在微波辐射计标定中的应用挑战","authors":"S. Sobjaerg, J. Balling, N. Skou","doi":"10.1109/MICRORAD.2012.6185258","DOIUrl":null,"url":null,"abstract":"Two Active Cold Loads (ACLs) for microwave radiometer calibration, operating at X-band, are evaluated with respect to important stability parameters. Using a stable radiometer system as test bed, absolute levels of 77 K and 55 K are found. This paper identifies and summarizes potential challenges and uncertainties in future application of ACLs in air and space borne missions, and important parameters, such as temperature sensitivity and long term stability are addressed. For the devices under test, temperature sensitivities are found to be in the range from 0.2 K/°C to 0.4 K/°C, and typical long term drift up to 1.5 K/year is estimated.","PeriodicalId":122743,"journal":{"name":"2012 12th Specialist Meeting on Microwave Radiometry and Remote Sensing of the Environment (MicroRad)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Challenges in application of Active Cold Loads for microwave radiometer calibration\",\"authors\":\"S. Sobjaerg, J. Balling, N. Skou\",\"doi\":\"10.1109/MICRORAD.2012.6185258\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Two Active Cold Loads (ACLs) for microwave radiometer calibration, operating at X-band, are evaluated with respect to important stability parameters. Using a stable radiometer system as test bed, absolute levels of 77 K and 55 K are found. This paper identifies and summarizes potential challenges and uncertainties in future application of ACLs in air and space borne missions, and important parameters, such as temperature sensitivity and long term stability are addressed. For the devices under test, temperature sensitivities are found to be in the range from 0.2 K/°C to 0.4 K/°C, and typical long term drift up to 1.5 K/year is estimated.\",\"PeriodicalId\":122743,\"journal\":{\"name\":\"2012 12th Specialist Meeting on Microwave Radiometry and Remote Sensing of the Environment (MicroRad)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 12th Specialist Meeting on Microwave Radiometry and Remote Sensing of the Environment (MicroRad)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MICRORAD.2012.6185258\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 12th Specialist Meeting on Microwave Radiometry and Remote Sensing of the Environment (MicroRad)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MICRORAD.2012.6185258","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

对两个用于x波段微波辐射计校准的主动冷负荷(ACLs)进行了重要稳定性参数的评估。用稳定的辐射计系统作为试验台,得到了77 K和55 K的绝对水平。本文识别并总结了未来在空载任务中应用ACLs的潜在挑战和不确定性,并讨论了温度灵敏度和长期稳定性等重要参数。对于测试中的器件,发现温度灵敏度在0.2 K/°C至0.4 K/°C的范围内,并且估计典型的长期漂移高达1.5 K/年。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Challenges in application of Active Cold Loads for microwave radiometer calibration
Two Active Cold Loads (ACLs) for microwave radiometer calibration, operating at X-band, are evaluated with respect to important stability parameters. Using a stable radiometer system as test bed, absolute levels of 77 K and 55 K are found. This paper identifies and summarizes potential challenges and uncertainties in future application of ACLs in air and space borne missions, and important parameters, such as temperature sensitivity and long term stability are addressed. For the devices under test, temperature sensitivities are found to be in the range from 0.2 K/°C to 0.4 K/°C, and typical long term drift up to 1.5 K/year is estimated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信