不同轴向虚拟支架部署引起的患者特异性颅内动脉瘤血流动力学改变

Minsuok Kim, I. Larrabide, M. Villa-Uriol, Alejandro F Frangi
{"title":"不同轴向虚拟支架部署引起的患者特异性颅内动脉瘤血流动力学改变","authors":"Minsuok Kim, I. Larrabide, M. Villa-Uriol, Alejandro F Frangi","doi":"10.1109/ISBI.2009.5193280","DOIUrl":null,"url":null,"abstract":"The aim of this study is to investigate the influence of stent axial orientation on saccular aneurysm hemodynamics. Two commercial stents, Neuroform stent (stent 1) and Zilver stent (stent 2) are modeled in this study. Both stents are virtually deployed with four different axial orientations to fit into the luminal surface of a patient-specific internal carotid artery (ICA) aneurysm model. Computational hemodynamic analyses are carried out in unstented and stented aneurysm models. The intra-aneurismal flows of stented aneurysm models show disturbed and complex flow patterns while the flow activities and the forces acting on the aneurysm wall are generally alleviated by stenting. The influence of the axial orientation of the stent on the aneurysm hemodynamics is more significant for stent 2 which has a larger strut size compared to stent 1. Interestingly, the flow activity in the aneurysm is rather increased when the intra-luminal scaffolding of stent is not sufficient.","PeriodicalId":272938,"journal":{"name":"2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Hemodynamic alterations of a patient-specific intracranial aneurysm induced by virtual deployment of stents in various axial orientation\",\"authors\":\"Minsuok Kim, I. Larrabide, M. Villa-Uriol, Alejandro F Frangi\",\"doi\":\"10.1109/ISBI.2009.5193280\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this study is to investigate the influence of stent axial orientation on saccular aneurysm hemodynamics. Two commercial stents, Neuroform stent (stent 1) and Zilver stent (stent 2) are modeled in this study. Both stents are virtually deployed with four different axial orientations to fit into the luminal surface of a patient-specific internal carotid artery (ICA) aneurysm model. Computational hemodynamic analyses are carried out in unstented and stented aneurysm models. The intra-aneurismal flows of stented aneurysm models show disturbed and complex flow patterns while the flow activities and the forces acting on the aneurysm wall are generally alleviated by stenting. The influence of the axial orientation of the stent on the aneurysm hemodynamics is more significant for stent 2 which has a larger strut size compared to stent 1. Interestingly, the flow activity in the aneurysm is rather increased when the intra-luminal scaffolding of stent is not sufficient.\",\"PeriodicalId\":272938,\"journal\":{\"name\":\"2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISBI.2009.5193280\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBI.2009.5193280","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本研究的目的是探讨支架轴向对囊性动脉瘤血流动力学的影响。本研究对两种商用支架Neuroform stent (stent 1)和Zilver stent (stent 2)进行了建模。两种支架都以四种不同的轴向进行虚拟部署,以适应患者特定的颈内动脉(ICA)动脉瘤模型的管腔表面。计算血流动力学分析在未支架和支架动脉瘤模型中进行。支架植入的动脉瘤模型的动脉瘤内流动表现出紊乱和复杂的流动模式,而支架植入通常会减轻流动活动和作用在动脉瘤壁上的力。支架2的支架柱尺寸比支架1大,支架轴向对动脉瘤血流动力学的影响更为显著。有趣的是,当腔内支架不充分时,动脉瘤内的血流活性反而增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Hemodynamic alterations of a patient-specific intracranial aneurysm induced by virtual deployment of stents in various axial orientation
The aim of this study is to investigate the influence of stent axial orientation on saccular aneurysm hemodynamics. Two commercial stents, Neuroform stent (stent 1) and Zilver stent (stent 2) are modeled in this study. Both stents are virtually deployed with four different axial orientations to fit into the luminal surface of a patient-specific internal carotid artery (ICA) aneurysm model. Computational hemodynamic analyses are carried out in unstented and stented aneurysm models. The intra-aneurismal flows of stented aneurysm models show disturbed and complex flow patterns while the flow activities and the forces acting on the aneurysm wall are generally alleviated by stenting. The influence of the axial orientation of the stent on the aneurysm hemodynamics is more significant for stent 2 which has a larger strut size compared to stent 1. Interestingly, the flow activity in the aneurysm is rather increased when the intra-luminal scaffolding of stent is not sufficient.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信