检查近场和远场地震下相邻建筑物之间的间距是否足够

Yazan M. Jaradat, H. Far, A. Saleh
{"title":"检查近场和远场地震下相邻建筑物之间的间距是否足够","authors":"Yazan M. Jaradat, H. Far, A. Saleh","doi":"10.2495/eres210061","DOIUrl":null,"url":null,"abstract":"Earthquake-induced pounding is a phenomenon that has been observed in almost every major earthquake since the 1960s. Pounding between adjacent buildings occurs due to insufficient separation and with different dynamic properties. This usually causes local damage, and in some extreme cases, total collapse of structures. Building codes in seismically active zones recommended a minimum separation gap between adjacent buildings to avoid pounding during severe earthquakes. AS1170.42007 is an Australian standard that requires 1% of the building height as a minimum separation gap between buildings to preclude pounding. This article presents experimental and numerical results to examine the adequacy of this specification to avoid seismic pounding between steel-frame structures under near-field and far-field earthquakes. It is found that AS1170.4-2007 is inadequate if the shorter building is used to estimate the required separation between adjacent structures under both near-field and far-field earthquakes. The code specification is adequate if the taller building is used to estimate the required separation between adjacent structures under far-field earthquakes only. The results are also compared with corresponding results obtained using the ABS and SRSS methods.","PeriodicalId":290397,"journal":{"name":"Earthquake Resistant Engineering Structures XIII","volume":"263 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"EXAMINING THE ADEQUACY OF SEPARATION GAPS BETWEEN ADJACENT BUILDINGS UNDER NEAR-FIELD AND FAR-FIELD EARTHQUAKES\",\"authors\":\"Yazan M. Jaradat, H. Far, A. Saleh\",\"doi\":\"10.2495/eres210061\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Earthquake-induced pounding is a phenomenon that has been observed in almost every major earthquake since the 1960s. Pounding between adjacent buildings occurs due to insufficient separation and with different dynamic properties. This usually causes local damage, and in some extreme cases, total collapse of structures. Building codes in seismically active zones recommended a minimum separation gap between adjacent buildings to avoid pounding during severe earthquakes. AS1170.42007 is an Australian standard that requires 1% of the building height as a minimum separation gap between buildings to preclude pounding. This article presents experimental and numerical results to examine the adequacy of this specification to avoid seismic pounding between steel-frame structures under near-field and far-field earthquakes. It is found that AS1170.4-2007 is inadequate if the shorter building is used to estimate the required separation between adjacent structures under both near-field and far-field earthquakes. The code specification is adequate if the taller building is used to estimate the required separation between adjacent structures under far-field earthquakes only. The results are also compared with corresponding results obtained using the ABS and SRSS methods.\",\"PeriodicalId\":290397,\"journal\":{\"name\":\"Earthquake Resistant Engineering Structures XIII\",\"volume\":\"263 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Earthquake Resistant Engineering Structures XIII\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2495/eres210061\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Earthquake Resistant Engineering Structures XIII","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2495/eres210061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

自20世纪60年代以来,地震诱发的震击现象几乎在每次大地震中都能观察到。相邻建筑之间由于分隔不充分,动力特性不同而产生碰撞。这通常会导致局部损坏,在某些极端情况下,会导致结构完全倒塌。地震活动区的建筑规范建议,相邻建筑物之间的间隔要最小,以避免在强烈地震时受到冲击。AS1170.42007是一项澳大利亚标准,要求建筑物之间的最小间距为建筑物高度的1%,以防止撞击。本文提出了试验和数值结果,以检验该规范是否足以避免钢框架结构在近场和远场地震下的震击。如果用较矮的建筑物来估计近场和远场地震下相邻结构之间所需的距离,则AS1170.4-2007是不充分的。如果高层建筑仅用于估计远场地震下相邻结构之间所需的间距,则规范规范是足够的。并与ABS法和SRSS法的结果进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
EXAMINING THE ADEQUACY OF SEPARATION GAPS BETWEEN ADJACENT BUILDINGS UNDER NEAR-FIELD AND FAR-FIELD EARTHQUAKES
Earthquake-induced pounding is a phenomenon that has been observed in almost every major earthquake since the 1960s. Pounding between adjacent buildings occurs due to insufficient separation and with different dynamic properties. This usually causes local damage, and in some extreme cases, total collapse of structures. Building codes in seismically active zones recommended a minimum separation gap between adjacent buildings to avoid pounding during severe earthquakes. AS1170.42007 is an Australian standard that requires 1% of the building height as a minimum separation gap between buildings to preclude pounding. This article presents experimental and numerical results to examine the adequacy of this specification to avoid seismic pounding between steel-frame structures under near-field and far-field earthquakes. It is found that AS1170.4-2007 is inadequate if the shorter building is used to estimate the required separation between adjacent structures under both near-field and far-field earthquakes. The code specification is adequate if the taller building is used to estimate the required separation between adjacent structures under far-field earthquakes only. The results are also compared with corresponding results obtained using the ABS and SRSS methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信