{"title":"利用电磁干扰垫片传输阻抗数据对屏蔽接头进行评估","authors":"A. Faught","doi":"10.1109/ISEMC.1982.7567716","DOIUrl":null,"url":null,"abstract":"The application of transfer impedance measurement techniques to characterize EMI shielding gasket mate rials produces data more useful to designers than do traditional shielded room techniques. Transfer imped ance, which is free of variations due to geometry and incident fields, allows more detailed evaluation of the roles played by shielding gaskets and their mating surfaces.","PeriodicalId":280076,"journal":{"name":"1982 IEEE International Symposium on Electromagnetic Compatibility","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1982-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"An Introduction to Shield Joint Evaluation Using EMI Gasket Transfer Impedance Data\",\"authors\":\"A. Faught\",\"doi\":\"10.1109/ISEMC.1982.7567716\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The application of transfer impedance measurement techniques to characterize EMI shielding gasket mate rials produces data more useful to designers than do traditional shielded room techniques. Transfer imped ance, which is free of variations due to geometry and incident fields, allows more detailed evaluation of the roles played by shielding gaskets and their mating surfaces.\",\"PeriodicalId\":280076,\"journal\":{\"name\":\"1982 IEEE International Symposium on Electromagnetic Compatibility\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1982-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1982 IEEE International Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.1982.7567716\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1982 IEEE International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1982.7567716","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An Introduction to Shield Joint Evaluation Using EMI Gasket Transfer Impedance Data
The application of transfer impedance measurement techniques to characterize EMI shielding gasket mate rials produces data more useful to designers than do traditional shielded room techniques. Transfer imped ance, which is free of variations due to geometry and incident fields, allows more detailed evaluation of the roles played by shielding gaskets and their mating surfaces.