采用颗粒状泡沫玻璃筛分层,减少烃类液体的蒸发

E. Shiryaev, V. Nazarov
{"title":"采用颗粒状泡沫玻璃筛分层,减少烃类液体的蒸发","authors":"E. Shiryaev, V. Nazarov","doi":"10.22227/0869-7493.2022.31.05.14-25","DOIUrl":null,"url":null,"abstract":"Introduction. The open surface of evaporation of hydrocarbon liquids during their storage in tanks (reservoirs) and in case of emergency spills are the fire hazards characterized by the mass rate of evaporation. The main way to reduce the fire hazard of hydrocarbon liquids is to isolate the evaporation surface of hydrocarbon liquids using various coatings, such as pontoons or floating roofs in tanks (reservoirs), and in case of emergency spills air-filled foam can be used, etc. An effective way to reduce the evaporation of hydrocarbon liquids is to isolate the evaporation surface using light slightly hygroscopic granular materials capable of being retained on the liquid surface by the Archimedean force. The authors address the analytical-experimental evaluation of a decrease in the mass rate of evaporation of hydrocarbon liquids when a layer of granulated foam glass shields the spill surface.Calculation methodology and results. A mathematical model has been developed to describe a reduction in the evaporation rate of hydrocarbon liquids through a “dry” layer of granulated foam glass, similar to the Bouguer – Lambert – Beer law. A method of experimental evaluation of the mass evaporation rate of hydrocarbon liquids through a shielding layer of granulated foam glass of different height has been developed. Screening coefficients for a number of hydrocarbon liquids and the averaged screening coefficient were identified using the results of an experimental research into parameters of evaporation of flammable liquids (acetone, gasoline AI-92, hexane, ethanol, kerosene, diesel fuel) through a “dry” layer of granulated foam glass of the Termoisol brand (fraction 5–7 mm) obtained using the methodology developed by the authors. Dependences between the rates of liquid evaporation through different thicknesses of a “dry” layer of granulated foam glass on the pressure of saturated vapours have been established. The area height, limited by the bottom concentration limit of the vapour flame, spreading during the evaporation of tested liquids from the free surface that may also have a shielding layer of Termoizol granulated foam glass is estimated analytically and experimentally.Conclusions. The developed mathematical model and the method of experimental estimation of the mass evaporation rate of hydrocarbon liquids allows to identify the evaporation rate of hydrocarbon liquids of different classes, and it can be used to study the parameters of evaporation shielded by materials having different granulo metric compositions.","PeriodicalId":169739,"journal":{"name":"Pozharovzryvobezopasnost/Fire and Explosion Safety","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Using the screening layer of granulated foam glass to reduce the evaporation of hydrocarbon liquids\",\"authors\":\"E. Shiryaev, V. Nazarov\",\"doi\":\"10.22227/0869-7493.2022.31.05.14-25\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction. The open surface of evaporation of hydrocarbon liquids during their storage in tanks (reservoirs) and in case of emergency spills are the fire hazards characterized by the mass rate of evaporation. The main way to reduce the fire hazard of hydrocarbon liquids is to isolate the evaporation surface of hydrocarbon liquids using various coatings, such as pontoons or floating roofs in tanks (reservoirs), and in case of emergency spills air-filled foam can be used, etc. An effective way to reduce the evaporation of hydrocarbon liquids is to isolate the evaporation surface using light slightly hygroscopic granular materials capable of being retained on the liquid surface by the Archimedean force. The authors address the analytical-experimental evaluation of a decrease in the mass rate of evaporation of hydrocarbon liquids when a layer of granulated foam glass shields the spill surface.Calculation methodology and results. A mathematical model has been developed to describe a reduction in the evaporation rate of hydrocarbon liquids through a “dry” layer of granulated foam glass, similar to the Bouguer – Lambert – Beer law. A method of experimental evaluation of the mass evaporation rate of hydrocarbon liquids through a shielding layer of granulated foam glass of different height has been developed. Screening coefficients for a number of hydrocarbon liquids and the averaged screening coefficient were identified using the results of an experimental research into parameters of evaporation of flammable liquids (acetone, gasoline AI-92, hexane, ethanol, kerosene, diesel fuel) through a “dry” layer of granulated foam glass of the Termoisol brand (fraction 5–7 mm) obtained using the methodology developed by the authors. Dependences between the rates of liquid evaporation through different thicknesses of a “dry” layer of granulated foam glass on the pressure of saturated vapours have been established. The area height, limited by the bottom concentration limit of the vapour flame, spreading during the evaporation of tested liquids from the free surface that may also have a shielding layer of Termoizol granulated foam glass is estimated analytically and experimentally.Conclusions. The developed mathematical model and the method of experimental estimation of the mass evaporation rate of hydrocarbon liquids allows to identify the evaporation rate of hydrocarbon liquids of different classes, and it can be used to study the parameters of evaporation shielded by materials having different granulo metric compositions.\",\"PeriodicalId\":169739,\"journal\":{\"name\":\"Pozharovzryvobezopasnost/Fire and Explosion Safety\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pozharovzryvobezopasnost/Fire and Explosion Safety\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22227/0869-7493.2022.31.05.14-25\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pozharovzryvobezopasnost/Fire and Explosion Safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22227/0869-7493.2022.31.05.14-25","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍。烃类液体在储罐(储层)中贮存和发生紧急泄漏时的开放蒸发面是火灾危险的特征,其特征是蒸发的质量速率。减少烃类液体火灾危险的主要途径是利用各种涂层隔离烃类液体的蒸发面,如储罐(库)中的浮桥或浮顶,在紧急情况下可以使用充气泡沫等。减少烃类液体蒸发的一种有效方法是使用轻质的微吸湿颗粒材料隔离蒸发表面,这些颗粒材料能够通过阿基米德力保留在液体表面上。作者讨论了当一层颗粒状泡沫玻璃屏蔽泄漏表面时,碳氢化合物液体蒸发质量率降低的分析-实验评估。计算方法及结果。已经建立了一个数学模型来描述碳氢化合物液体通过颗粒状泡沫玻璃的“干”层蒸发速率的减少,类似于布格-兰伯特-比尔定律。提出了一种通过不同高度的泡沫玻璃屏蔽层测定烃类液体质量蒸发速率的实验方法。使用作者开发的方法,对可燃液体(丙酮、汽油AI-92、己烷、乙醇、煤油、柴油)通过Termoisol品牌(分数5 - 7mm)的颗粒状泡沫玻璃“干”层的蒸发参数进行了实验研究,得出了许多碳氢化合物液体的筛选系数和平均筛选系数。通过不同厚度的“干”泡沫玻璃颗粒层的液体蒸发速率与饱和蒸汽压力之间的关系已经确立。在被测液体蒸发过程中,受蒸汽火焰的下限浓度限制,从可能有Termoizol颗粒泡沫玻璃屏蔽层的自由表面上蔓延的区域高度进行了分析和实验估计。所建立的烃类液体质量蒸发速率的数学模型和实验估计方法,可以识别不同类别烃类液体的蒸发速率,并可用于研究不同颗粒度组成的物质屏蔽蒸发的参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Using the screening layer of granulated foam glass to reduce the evaporation of hydrocarbon liquids
Introduction. The open surface of evaporation of hydrocarbon liquids during their storage in tanks (reservoirs) and in case of emergency spills are the fire hazards characterized by the mass rate of evaporation. The main way to reduce the fire hazard of hydrocarbon liquids is to isolate the evaporation surface of hydrocarbon liquids using various coatings, such as pontoons or floating roofs in tanks (reservoirs), and in case of emergency spills air-filled foam can be used, etc. An effective way to reduce the evaporation of hydrocarbon liquids is to isolate the evaporation surface using light slightly hygroscopic granular materials capable of being retained on the liquid surface by the Archimedean force. The authors address the analytical-experimental evaluation of a decrease in the mass rate of evaporation of hydrocarbon liquids when a layer of granulated foam glass shields the spill surface.Calculation methodology and results. A mathematical model has been developed to describe a reduction in the evaporation rate of hydrocarbon liquids through a “dry” layer of granulated foam glass, similar to the Bouguer – Lambert – Beer law. A method of experimental evaluation of the mass evaporation rate of hydrocarbon liquids through a shielding layer of granulated foam glass of different height has been developed. Screening coefficients for a number of hydrocarbon liquids and the averaged screening coefficient were identified using the results of an experimental research into parameters of evaporation of flammable liquids (acetone, gasoline AI-92, hexane, ethanol, kerosene, diesel fuel) through a “dry” layer of granulated foam glass of the Termoisol brand (fraction 5–7 mm) obtained using the methodology developed by the authors. Dependences between the rates of liquid evaporation through different thicknesses of a “dry” layer of granulated foam glass on the pressure of saturated vapours have been established. The area height, limited by the bottom concentration limit of the vapour flame, spreading during the evaporation of tested liquids from the free surface that may also have a shielding layer of Termoizol granulated foam glass is estimated analytically and experimentally.Conclusions. The developed mathematical model and the method of experimental estimation of the mass evaporation rate of hydrocarbon liquids allows to identify the evaporation rate of hydrocarbon liquids of different classes, and it can be used to study the parameters of evaporation shielded by materials having different granulo metric compositions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信