基于物理模型的布测低出生体重婴儿非接触心电图研究

Tsukasa Aihara, A. Ueno
{"title":"基于物理模型的布测低出生体重婴儿非接触心电图研究","authors":"Tsukasa Aihara, A. Ueno","doi":"10.1109/BMEiCON53485.2021.9745228","DOIUrl":null,"url":null,"abstract":"In the measurements of low birth weight infants, some non-body-worn electrodes or sensors are preferred because their attachment can lead to sudden change in the condition of the infants. The authors of this paper measured and compared the capacitive electrocardiogram signals from a mock-up infant model with a low birth weight through a cotton towel using a sheeting electrode with a driven shield and an old and a new type of analog front ends (AFEs). By reducing the total gain of the measurement system from 40 to 20 dB and replacing the earlier AFE with a new one, ECG waveforms that involved P, R, and T waves were observed from the 1600-g mock-up model. Repetitive R waves were also observed from the 700-g mock-up model under the same system.","PeriodicalId":380002,"journal":{"name":"2021 13th Biomedical Engineering International Conference (BMEiCON)","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Physical Model-based Study on Non-Contact Electrocardiogram Measurement of Low Birth Weight Infants in Incubators through a Cloth\",\"authors\":\"Tsukasa Aihara, A. Ueno\",\"doi\":\"10.1109/BMEiCON53485.2021.9745228\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the measurements of low birth weight infants, some non-body-worn electrodes or sensors are preferred because their attachment can lead to sudden change in the condition of the infants. The authors of this paper measured and compared the capacitive electrocardiogram signals from a mock-up infant model with a low birth weight through a cotton towel using a sheeting electrode with a driven shield and an old and a new type of analog front ends (AFEs). By reducing the total gain of the measurement system from 40 to 20 dB and replacing the earlier AFE with a new one, ECG waveforms that involved P, R, and T waves were observed from the 1600-g mock-up model. Repetitive R waves were also observed from the 700-g mock-up model under the same system.\",\"PeriodicalId\":380002,\"journal\":{\"name\":\"2021 13th Biomedical Engineering International Conference (BMEiCON)\",\"volume\":\"67 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 13th Biomedical Engineering International Conference (BMEiCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BMEiCON53485.2021.9745228\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 13th Biomedical Engineering International Conference (BMEiCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BMEiCON53485.2021.9745228","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在低出生体重婴儿的测量中,一些非身体磨损的电极或传感器是首选的,因为它们的附着会导致婴儿状况的突然变化。本文采用带驱动屏蔽的片状电极和新型模拟前端(AFEs),通过棉巾测量并比较了低出生体重婴儿模型的电容性心电图信号。通过将测量系统的总增益从40 dB降低到20 dB,并将早期的AFE替换为新的AFE,从1600 g模型中观察到涉及P, R和T波的心电波形。在相同的系统下,700克的模型也观察到重复的R波。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Physical Model-based Study on Non-Contact Electrocardiogram Measurement of Low Birth Weight Infants in Incubators through a Cloth
In the measurements of low birth weight infants, some non-body-worn electrodes or sensors are preferred because their attachment can lead to sudden change in the condition of the infants. The authors of this paper measured and compared the capacitive electrocardiogram signals from a mock-up infant model with a low birth weight through a cotton towel using a sheeting electrode with a driven shield and an old and a new type of analog front ends (AFEs). By reducing the total gain of the measurement system from 40 to 20 dB and replacing the earlier AFE with a new one, ECG waveforms that involved P, R, and T waves were observed from the 1600-g mock-up model. Repetitive R waves were also observed from the 700-g mock-up model under the same system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信