{"title":"电能质量分析仪用参考方波信号标定电压和电流谐波及测量和处理算法","authors":"P. Tzvetkov, K. Galabov, A. Serov, I. Kodjabashev","doi":"10.1109/MMA52675.2021.9610939","DOIUrl":null,"url":null,"abstract":"The possibility for calibrating Power Quality Analyzer by harmonics is presented by using a reference square waveform signal. Based on the calibration model, a control algorithm is synthesized of the calibration measurement procedures and the processing of the uncertainty of the calibration results. Results from the calibration of the Fluke 435 analyzer with the Metrix CX1651 calibrator on voltage and current harmonics are presented, which confirm the possibilities of using the reference square waveform signal.","PeriodicalId":287017,"journal":{"name":"2021 XXXI International Scientific Symposium Metrology and Metrology Assurance (MMA)","volume":"220 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Power Quality Analyzers Calibration on Harmonics of Voltage and Current by Reference Square Waveform Signal and Algorithm for Measurement ang Processing\",\"authors\":\"P. Tzvetkov, K. Galabov, A. Serov, I. Kodjabashev\",\"doi\":\"10.1109/MMA52675.2021.9610939\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The possibility for calibrating Power Quality Analyzer by harmonics is presented by using a reference square waveform signal. Based on the calibration model, a control algorithm is synthesized of the calibration measurement procedures and the processing of the uncertainty of the calibration results. Results from the calibration of the Fluke 435 analyzer with the Metrix CX1651 calibrator on voltage and current harmonics are presented, which confirm the possibilities of using the reference square waveform signal.\",\"PeriodicalId\":287017,\"journal\":{\"name\":\"2021 XXXI International Scientific Symposium Metrology and Metrology Assurance (MMA)\",\"volume\":\"220 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 XXXI International Scientific Symposium Metrology and Metrology Assurance (MMA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MMA52675.2021.9610939\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 XXXI International Scientific Symposium Metrology and Metrology Assurance (MMA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MMA52675.2021.9610939","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Power Quality Analyzers Calibration on Harmonics of Voltage and Current by Reference Square Waveform Signal and Algorithm for Measurement ang Processing
The possibility for calibrating Power Quality Analyzer by harmonics is presented by using a reference square waveform signal. Based on the calibration model, a control algorithm is synthesized of the calibration measurement procedures and the processing of the uncertainty of the calibration results. Results from the calibration of the Fluke 435 analyzer with the Metrix CX1651 calibrator on voltage and current harmonics are presented, which confirm the possibilities of using the reference square waveform signal.