DMM校准间隔自动测量站的实现

C. D. Capua, D. Grillo, E. Romeo
{"title":"DMM校准间隔自动测量站的实现","authors":"C. D. Capua, D. Grillo, E. Romeo","doi":"10.1109/VECIMS.2006.250790","DOIUrl":null,"url":null,"abstract":"In the present work the authors present a procedure for the determination of the optimal calibration intervals of a measurement instrument according to the reference Standard. Generally speaking, the goal of a calibration process is to reduce out-of tolerance occurrences to an acceptable level with respect to the desired quality target. The approach is based on the monitoring of the capability of an instrument in making measurements in conformity with the accuracy declared in the datasheet provided by the manufacturer. Periodic actions are required for the metrological confirmation, effected in a laboratory of tests, using for this purpose a reference instrument. In this paper is presented the implementation of an automatic station of measurement which performs an original procedure able to forecast the time to wait for the next calibration process","PeriodicalId":405572,"journal":{"name":"2006 IEEE Symposium on Virtual Environments, Human-Computer Interfaces and Measurement Systems","volume":"93 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"The Implementation of an Automatic Measurement Station for the Determination of the Calibration Intervals for a DMM\",\"authors\":\"C. D. Capua, D. Grillo, E. Romeo\",\"doi\":\"10.1109/VECIMS.2006.250790\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the present work the authors present a procedure for the determination of the optimal calibration intervals of a measurement instrument according to the reference Standard. Generally speaking, the goal of a calibration process is to reduce out-of tolerance occurrences to an acceptable level with respect to the desired quality target. The approach is based on the monitoring of the capability of an instrument in making measurements in conformity with the accuracy declared in the datasheet provided by the manufacturer. Periodic actions are required for the metrological confirmation, effected in a laboratory of tests, using for this purpose a reference instrument. In this paper is presented the implementation of an automatic station of measurement which performs an original procedure able to forecast the time to wait for the next calibration process\",\"PeriodicalId\":405572,\"journal\":{\"name\":\"2006 IEEE Symposium on Virtual Environments, Human-Computer Interfaces and Measurement Systems\",\"volume\":\"93 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE Symposium on Virtual Environments, Human-Computer Interfaces and Measurement Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/VECIMS.2006.250790\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Symposium on Virtual Environments, Human-Computer Interfaces and Measurement Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VECIMS.2006.250790","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

在本工作中,作者提出了一种根据参考标准确定测量仪器最佳校准间隔的方法。一般来说,校准过程的目标是将超出公差的情况减少到相对于期望的质量目标可接受的水平。该方法是基于监测仪器进行测量的能力,以符合制造商提供的数据表中声明的精度。在测试实验室中使用参考仪器进行计量确认时,需要进行周期性的操作。本文介绍了一种自动测量站的实现方法,该自动测量站执行一个原始程序,能够预测等待下一个校准过程的时间
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Implementation of an Automatic Measurement Station for the Determination of the Calibration Intervals for a DMM
In the present work the authors present a procedure for the determination of the optimal calibration intervals of a measurement instrument according to the reference Standard. Generally speaking, the goal of a calibration process is to reduce out-of tolerance occurrences to an acceptable level with respect to the desired quality target. The approach is based on the monitoring of the capability of an instrument in making measurements in conformity with the accuracy declared in the datasheet provided by the manufacturer. Periodic actions are required for the metrological confirmation, effected in a laboratory of tests, using for this purpose a reference instrument. In this paper is presented the implementation of an automatic station of measurement which performs an original procedure able to forecast the time to wait for the next calibration process
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信