孟加拉电力系统东西互联线串联与串联并联补偿的比较

M. Alam, A. Chowdhury, M. N. Hasan
{"title":"孟加拉电力系统东西互联线串联与串联并联补偿的比较","authors":"M. Alam, A. Chowdhury, M. N. Hasan","doi":"10.1109/ICAEE.2015.7506850","DOIUrl":null,"url":null,"abstract":"Utilization of the existing transmission line capacity to its fullest is most important due to the continuous growth of the demand and rising cost of new transmission infrastructures. Due to the problems associated with voltage drop and stability limits, a transmission line can not be loaded up to its thermal limit. The potential benefits of installing Flexible AC Transmission System (FACTS) devices on the system for enhancing power transmission capacity and stability are well known. Two main members of FACTS family like thyristor controlled series capacitor (TCSC) and static var compensator (SVC) have been widely studied and reported in technical literature and have been shown as effective as well as time saving alternative to building new transmission lines for enhancing power transmission capacity and stability. This paper compares the application of series and series-shunt compensation by means of TCSC and SVC to show enhancement of power transmission capacity and stability of East-West Interconnected System (EWIS) of Bangladesh Power System (BPS). Two SVCs are connected in parallel with two buses in the western region of the interconnectors and two TCSCs are connected in series with the interconnectors. Bifurcation, steady state, and transient analyses are performed to compare positive effect of series and series-shunt compensation on transmission capacity and stability in BPS network.","PeriodicalId":123939,"journal":{"name":"2015 International Conference on Advances in Electrical Engineering (ICAEE)","volume":"2 4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Comparison of series and combined series-shunt compensation on East-West Interconnectors of Bangladesh Power System\",\"authors\":\"M. Alam, A. Chowdhury, M. N. Hasan\",\"doi\":\"10.1109/ICAEE.2015.7506850\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Utilization of the existing transmission line capacity to its fullest is most important due to the continuous growth of the demand and rising cost of new transmission infrastructures. Due to the problems associated with voltage drop and stability limits, a transmission line can not be loaded up to its thermal limit. The potential benefits of installing Flexible AC Transmission System (FACTS) devices on the system for enhancing power transmission capacity and stability are well known. Two main members of FACTS family like thyristor controlled series capacitor (TCSC) and static var compensator (SVC) have been widely studied and reported in technical literature and have been shown as effective as well as time saving alternative to building new transmission lines for enhancing power transmission capacity and stability. This paper compares the application of series and series-shunt compensation by means of TCSC and SVC to show enhancement of power transmission capacity and stability of East-West Interconnected System (EWIS) of Bangladesh Power System (BPS). Two SVCs are connected in parallel with two buses in the western region of the interconnectors and two TCSCs are connected in series with the interconnectors. Bifurcation, steady state, and transient analyses are performed to compare positive effect of series and series-shunt compensation on transmission capacity and stability in BPS network.\",\"PeriodicalId\":123939,\"journal\":{\"name\":\"2015 International Conference on Advances in Electrical Engineering (ICAEE)\",\"volume\":\"2 4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Advances in Electrical Engineering (ICAEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAEE.2015.7506850\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Advances in Electrical Engineering (ICAEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAEE.2015.7506850","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

由于新输电基础设施的需求不断增长和成本不断上升,最大限度地利用现有输电线路容量是最重要的。由于与电压降和稳定性限制有关的问题,传输线不能负载到其热极限。在系统上安装柔性交流输电系统(FACTS)设备对提高电力传输容量和稳定性的潜在好处是众所周知的。FACTS家族的两个主要成员如晶闸管控制串联电容器(TCSC)和静态无功补偿器(SVC)已经在技术文献中得到了广泛的研究和报道,并且已经被证明是建立新的输电线路的有效和节省时间的替代方案,以提高输电容量和稳定性。通过对串联补偿和串联并联补偿的TCSC补偿和SVC补偿的比较,说明了孟加拉国电力系统(BPS)的东西互联系统(EWIS)的输电容量和稳定性的提高。两个svc与互连线西部的两条母线并联,两个tcsc与互连线串联。通过分岔分析、稳态分析和暂态分析,比较了串联补偿和串联并联补偿对BPS网络传输容量和稳定性的积极影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of series and combined series-shunt compensation on East-West Interconnectors of Bangladesh Power System
Utilization of the existing transmission line capacity to its fullest is most important due to the continuous growth of the demand and rising cost of new transmission infrastructures. Due to the problems associated with voltage drop and stability limits, a transmission line can not be loaded up to its thermal limit. The potential benefits of installing Flexible AC Transmission System (FACTS) devices on the system for enhancing power transmission capacity and stability are well known. Two main members of FACTS family like thyristor controlled series capacitor (TCSC) and static var compensator (SVC) have been widely studied and reported in technical literature and have been shown as effective as well as time saving alternative to building new transmission lines for enhancing power transmission capacity and stability. This paper compares the application of series and series-shunt compensation by means of TCSC and SVC to show enhancement of power transmission capacity and stability of East-West Interconnected System (EWIS) of Bangladesh Power System (BPS). Two SVCs are connected in parallel with two buses in the western region of the interconnectors and two TCSCs are connected in series with the interconnectors. Bifurcation, steady state, and transient analyses are performed to compare positive effect of series and series-shunt compensation on transmission capacity and stability in BPS network.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信