一种基于磁滞的UPFC控制新方法

M. F. Moghadam, V. R. Disfani, H. Abyaneh, F. Razavi
{"title":"一种基于磁滞的UPFC控制新方法","authors":"M. F. Moghadam, V. R. Disfani, H. Abyaneh, F. Razavi","doi":"10.1109/PEOCO.2010.5559203","DOIUrl":null,"url":null,"abstract":"Appropriate design and use of Unified Power Flow Controller (UPFC), which has the ability of controlling the bus voltage level and transmission line power flow simultaneously, provides suitable conditions to improve restructured power systems operation. In this paper, a novel control method is proposed for Hysteresis based UPFC, which uses four degrees of freedom to control bus voltage, DC link voltage, and active and reactive transmission line power flows independently. Results obtained by simulations with PSCAD/EMTDC show that proposed control method is more effective than the reported methods in achieving better power quality indices and more stability i.e. less overshoots and settling times.","PeriodicalId":379868,"journal":{"name":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","volume":"80 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A novel method for Hysteresis based control of UPFC\",\"authors\":\"M. F. Moghadam, V. R. Disfani, H. Abyaneh, F. Razavi\",\"doi\":\"10.1109/PEOCO.2010.5559203\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Appropriate design and use of Unified Power Flow Controller (UPFC), which has the ability of controlling the bus voltage level and transmission line power flow simultaneously, provides suitable conditions to improve restructured power systems operation. In this paper, a novel control method is proposed for Hysteresis based UPFC, which uses four degrees of freedom to control bus voltage, DC link voltage, and active and reactive transmission line power flows independently. Results obtained by simulations with PSCAD/EMTDC show that proposed control method is more effective than the reported methods in achieving better power quality indices and more stability i.e. less overshoots and settling times.\",\"PeriodicalId\":379868,\"journal\":{\"name\":\"2010 4th International Power Engineering and Optimization Conference (PEOCO)\",\"volume\":\"80 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 4th International Power Engineering and Optimization Conference (PEOCO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEOCO.2010.5559203\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEOCO.2010.5559203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

统一潮流控制器(Unified Power Flow Controller, UPFC)具有同时控制母线电压水平和输电线路潮流的能力,合理设计和使用UPFC,为改进改造后电力系统的运行提供了适宜的条件。本文提出了一种新的基于磁滞的UPFC控制方法,该方法采用四自由度独立控制母线电压、直流链路电压以及输电线路有功和无功潮流。在PSCAD/EMTDC上的仿真结果表明,该控制方法在获得更好的电能质量指标和更高的稳定性(即更少的超调和稳定时间)方面比现有方法更有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A novel method for Hysteresis based control of UPFC
Appropriate design and use of Unified Power Flow Controller (UPFC), which has the ability of controlling the bus voltage level and transmission line power flow simultaneously, provides suitable conditions to improve restructured power systems operation. In this paper, a novel control method is proposed for Hysteresis based UPFC, which uses four degrees of freedom to control bus voltage, DC link voltage, and active and reactive transmission line power flows independently. Results obtained by simulations with PSCAD/EMTDC show that proposed control method is more effective than the reported methods in achieving better power quality indices and more stability i.e. less overshoots and settling times.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信