M. F. Moghadam, V. R. Disfani, H. Abyaneh, F. Razavi
{"title":"一种基于磁滞的UPFC控制新方法","authors":"M. F. Moghadam, V. R. Disfani, H. Abyaneh, F. Razavi","doi":"10.1109/PEOCO.2010.5559203","DOIUrl":null,"url":null,"abstract":"Appropriate design and use of Unified Power Flow Controller (UPFC), which has the ability of controlling the bus voltage level and transmission line power flow simultaneously, provides suitable conditions to improve restructured power systems operation. In this paper, a novel control method is proposed for Hysteresis based UPFC, which uses four degrees of freedom to control bus voltage, DC link voltage, and active and reactive transmission line power flows independently. Results obtained by simulations with PSCAD/EMTDC show that proposed control method is more effective than the reported methods in achieving better power quality indices and more stability i.e. less overshoots and settling times.","PeriodicalId":379868,"journal":{"name":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","volume":"80 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A novel method for Hysteresis based control of UPFC\",\"authors\":\"M. F. Moghadam, V. R. Disfani, H. Abyaneh, F. Razavi\",\"doi\":\"10.1109/PEOCO.2010.5559203\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Appropriate design and use of Unified Power Flow Controller (UPFC), which has the ability of controlling the bus voltage level and transmission line power flow simultaneously, provides suitable conditions to improve restructured power systems operation. In this paper, a novel control method is proposed for Hysteresis based UPFC, which uses four degrees of freedom to control bus voltage, DC link voltage, and active and reactive transmission line power flows independently. Results obtained by simulations with PSCAD/EMTDC show that proposed control method is more effective than the reported methods in achieving better power quality indices and more stability i.e. less overshoots and settling times.\",\"PeriodicalId\":379868,\"journal\":{\"name\":\"2010 4th International Power Engineering and Optimization Conference (PEOCO)\",\"volume\":\"80 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 4th International Power Engineering and Optimization Conference (PEOCO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEOCO.2010.5559203\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEOCO.2010.5559203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
统一潮流控制器(Unified Power Flow Controller, UPFC)具有同时控制母线电压水平和输电线路潮流的能力,合理设计和使用UPFC,为改进改造后电力系统的运行提供了适宜的条件。本文提出了一种新的基于磁滞的UPFC控制方法,该方法采用四自由度独立控制母线电压、直流链路电压以及输电线路有功和无功潮流。在PSCAD/EMTDC上的仿真结果表明,该控制方法在获得更好的电能质量指标和更高的稳定性(即更少的超调和稳定时间)方面比现有方法更有效。
A novel method for Hysteresis based control of UPFC
Appropriate design and use of Unified Power Flow Controller (UPFC), which has the ability of controlling the bus voltage level and transmission line power flow simultaneously, provides suitable conditions to improve restructured power systems operation. In this paper, a novel control method is proposed for Hysteresis based UPFC, which uses four degrees of freedom to control bus voltage, DC link voltage, and active and reactive transmission line power flows independently. Results obtained by simulations with PSCAD/EMTDC show that proposed control method is more effective than the reported methods in achieving better power quality indices and more stability i.e. less overshoots and settling times.