包括分散发电系统在内的配电网随机潮流

Jérôme Buire, F. Colas, J. Dieulot, Léticia De Alvaro, X. Guillaud
{"title":"包括分散发电系统在内的配电网随机潮流","authors":"Jérôme Buire, F. Colas, J. Dieulot, Léticia De Alvaro, X. Guillaud","doi":"10.1109/ISGTEurope.2018.8571753","DOIUrl":null,"url":null,"abstract":"The insertion of stochastic renewable energies in distribution grids generates important voltage fluctuations. However, the influence of the On Load Tap Changer and Distributed Generators (DGs) controllers, and specifically the existence of dead-bands in the control laws, has been seldom evaluated. Under the assumptions of Gaussian inputs and a linear model of the grid, it is shown that node voltages can be approximated either by Gaussian variables or sums of truncated Gaussian variables. A procedure is necessary to select the Probability Density Function (PDF) which fits best each node voltage. A signal based method and another algorithm relying on the grid topology are presented and compared when the modeling is applied to a real distribution grid. The model is accurate and can be used for confidence level or chance-constrained optimization of control parameters.","PeriodicalId":302863,"journal":{"name":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","volume":"99 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Stochastic power flow of distribution networks including dispersed generation system\",\"authors\":\"Jérôme Buire, F. Colas, J. Dieulot, Léticia De Alvaro, X. Guillaud\",\"doi\":\"10.1109/ISGTEurope.2018.8571753\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The insertion of stochastic renewable energies in distribution grids generates important voltage fluctuations. However, the influence of the On Load Tap Changer and Distributed Generators (DGs) controllers, and specifically the existence of dead-bands in the control laws, has been seldom evaluated. Under the assumptions of Gaussian inputs and a linear model of the grid, it is shown that node voltages can be approximated either by Gaussian variables or sums of truncated Gaussian variables. A procedure is necessary to select the Probability Density Function (PDF) which fits best each node voltage. A signal based method and another algorithm relying on the grid topology are presented and compared when the modeling is applied to a real distribution grid. The model is accurate and can be used for confidence level or chance-constrained optimization of control parameters.\",\"PeriodicalId\":302863,\"journal\":{\"name\":\"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"volume\":\"99 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEurope.2018.8571753\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEurope.2018.8571753","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

随机可再生能源在配电网中的插入会产生重要的电压波动。然而,有载分接开关和分布式发电机(dg)控制器的影响,特别是控制律中死带的存在,很少被评估。在高斯输入和电网线性模型的假设下,证明了节点电压既可以用高斯变量逼近,也可以用截断的高斯变量求和逼近。需要一个程序来选择最适合每个节点电压的概率密度函数。给出了一种基于信号的方法和另一种基于网格拓扑的方法,并将其应用于实际配电网中进行了比较。该模型精度高,可用于控制参数的置信水平或机会约束优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Stochastic power flow of distribution networks including dispersed generation system
The insertion of stochastic renewable energies in distribution grids generates important voltage fluctuations. However, the influence of the On Load Tap Changer and Distributed Generators (DGs) controllers, and specifically the existence of dead-bands in the control laws, has been seldom evaluated. Under the assumptions of Gaussian inputs and a linear model of the grid, it is shown that node voltages can be approximated either by Gaussian variables or sums of truncated Gaussian variables. A procedure is necessary to select the Probability Density Function (PDF) which fits best each node voltage. A signal based method and another algorithm relying on the grid topology are presented and compared when the modeling is applied to a real distribution grid. The model is accurate and can be used for confidence level or chance-constrained optimization of control parameters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信